©Johnstone Supply eCatalog 216
HVAC EQUIPMENT Daikin Commercial Split Systems
Air Conditioning Condensing Units 11.2 EER, Three-Phase, 7-1/2 & 10 Ton, R410A • Two-stage energy-efficient compressor • Factory-installed filter-drier
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• Copper tube enhanced aluminum fin coil • Brass liquid and suction service valves • High- and low-pressure switches • Complies with ASHRAE Standard 90.1 • Steel louver coil guard
Min. Circuit Amps
Order #
Mfg. #
Nom. Tons
BtuH Cooling
Max. Fuse Size Liquid Conn.
Suction Fitting Width
Height
Depth
Wt. Lbs.
208/230V B60-946
DX11TA0903 7-1/2 DX11TA1203 10 DX11TA0904 7-1/2 DX11TA1204 10
93,000 120,000 93,000 120,000
39.2 46.4
60 70 30 35
5/8" 5/8" 5/8" 5/8"
1-3/8" 1-3/8" 1-3/8" 1-3/8"
35-1/2" 35-1/2" 35-1/2" 35-1/2"
41-1/2" 41-1/2" 41-1/2" 41-1/2"
35-1/2" 35-1/2" 35-1/2" 35-1/2"
325 345 325 340
B60-948 460V B60-947 B60-949
18.5 22.0
Air Handlers Commercial DAT Series, Multi-Position, Two-Speed • Upflow or horizontal left positions in 7-1/2 & 10 ton cooling only or heat pump applications • 2-speed blower motor • TXV control • Draw-thru belt centrifugal blower • Horizontal and vertical condensate pans • Copper tube /aluminum fin coils
• Entry on top panel for both low and high voltage • Built-in filter rack with 2" filter supplied • Removable access panels • AHKD heat kits sold separately Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Note: * For two refrigerant lines
Order #
Mfg. #
Nom. Tons
Min. Circuit Amps Liquid Conn.
Suction Fitting
Width
Height
Depth
Wt. Lbs.
208/230V L93-323
DAT09043 7-1/2 DAT12043 10 DAT09044 7-1/2 DAT12044 10
7.5 7.5
3/8" (2)* 3/8" (2)* 3/8" (2)* 3/8" (2)*
1-1/8" (2)* 1-1/8" (2)* 1-1/8" (2)* 1-1/8" (2)*
48-1/8" 48-1/8" 48-1/8" 48-1/8"
24" 24" 24" 24"
60-1/2" 60-1/2" 60-1/2" 60-1/2"
430 430 430 430
L93-325 460V L93-324 L93-326
3.63 3.63
Heat Kits Single-Phase • For use with Goodman & Daikin packaged air conditioners and heat pumps
• 208/240V
Order # Mfg. # L80-209 EHK1-10
Nom. kW For Use With
10.0 15.0 18.0 20.0
GPH16M/DPH16M/DTC/DTH 3-6 Ton GPH16M/DPH16M/DTC/DTH 3-6 Ton GPH16M/DPH16M/DTC/DTH 3-6 Ton GPH16M/DPH16M/DTC/DTH 3-6 Ton
L80-213 L80-267 L80-217
EHK1-15 EHK1-18 EHK1-20
Heat Kits Three-Phase • For use with Daikin packaged air conditioners and heat pumps
• 208/240V
Order # Mfg. #
Nom. kW Volts
For Use With
Order # Mfg. #
Nom. kW Volts
For Use With
L80-210 L80-214 L80-268 L80-269 L80-218 L80-270
L80-211 L80-215 L80-272 L80-273 L80-219 L80-274 L81-015 L80-275 L81-016 L81-017 L81-018
EHK3-10 10.0 EHK3-15 15.0 EHK3-16 16.0 EHK3-18 18.0 EHK3-20 20.0 EHK3-30 30.0 EHK3-45 45.0 EHK3-46 43.2
208/240 CPC/CPH/DCC/DCH 3-6 Ton 208/240 CPC/CPH/DCC/DCH 3-6 Ton 208/240 DCC/DCH 7.5-12.5 Ton
EHK4-10 10.0 EHK4-15 15.0 EHK4-16 16.0 EHK4-18 18.0 EHK4-20 20.0 EHK4-30 30.0 EHK4-31 28.8 EHK4-45 45.0 EHK4-46 43.2 EHK4-60 57.6 EHK4-75 72.0
460 460 460 460 460 460 460 460 460 460 460
CPC/CPH/DCC/DCH 3-6 Ton CPC/CPH/DCC/DCH 3-6 Ton
DCC/DCH 7.5-12.5 Ton
208/240 CPC/CPH 4 Ton
CPC/CPH 4 Ton CPC/CPH 5-6 Ton
208/240 CPC/CPH/DCH/DCC/DCH 5-6 Ton
208/240 DCC/DCH 7.5-12.5 Ton
DCC/DCH 7.5-12.5 Ton
L80-980 EHK3-31 28.8
208/240 CPC180***3B
CPC180***3B
L80-271 L80-981
208/240 DCC/DCH 7.5-12.5 Ton
DCC/DCH 7.5-12.5 Ton
208/240 CPC 15-20Ton 208/240 CPC 15-20Ton 208/240 CPC 20Ton
CPC 15-20Ton CPC 15-20Ton
L80-982 EHK3-60 57.6
L81-014
EHK3-75 72.0
CPC 20Ton
758
©2023 Johnstone Supply, LLC
Made with FlippingBook Annual report maker