HVAC EQUIPMENT Daikin Commercial Packaged Units
BtuH Heating Input
BtuH Heating Output
Min. Circuit Amps
Order #
Mfg. #
Nom. Tons BtuH Cooling
EER
Nom. CFM
Width
Height
Depth
Wt. Lbs.
Low Heat - 460V B64-796
DRG0904DL00001S 7.5 DRG1024DL00001S 8.5 DRG1204DL00001S 10 DRG1504DL00001S 12.5 DRG0904DM00001S 7.5 DRG1024DM00001S 8.5 DRG1204DM00001S 10 DRG1504DM00001S 12.5 DRG0904DH00001S 7.5 DRG1024DH00001S 8.5 DRG1204DH00001S 10 DRG1504DH00001S 12.5
90,000 130000 105,300 12.2 102,000 130,000 105,300 12.2 115,000 130,000 105,300 12.2 137,000 130,000 105,300 11.5 90,000 180,000 145,800 12.2 102,000 180,000 145,800 12.2 115,000 180,000 145,800 12.2 137,000 180,000 145,800 11.5 90,000 225,000 182,250 12.2 102,000 225,000 182,250 12.2 115,000 240,000 194,400 12.2 137,000 240,000 194,400 11.5
3,000 3,100 3,550 3,800 3,000 3,100 3,550 3,800 3,000 3,100 3,550 3,800
20.8 21.4
93-3/4" 93-3/4" 93-3/4" 93-3/4" 93-3/4" 93-3/4" 93-3/4" 93-3/4" 93-3/4" 93-3/4" 93-3/4" 93-3/4"
54-9/20" 54-9/20" 54-9/20" 58-3/5" 54-9/20" 54-9/20" 54-9/20" 58-3/5" 54-9/20" 54-9/20" 54-9/20" 58-3/5"
60-3/8" 60-3/8" 60-3/8" 60-3/8" 60-3/8" 60-3/8" 60-3/8" 60-3/8" 60-3/8" 60-3/8" 60-3/8" 60-3/8"
1,162 1,173 1,192 1,270 1,172 1,183 1,202 1,280 1,181 1,192 1,215 1,293
B64-802 B64-808 B64-814
23
32.3
Medium Heat - 460V B64-797
20.8 21.4
B64-803 B64-809 B64-815
23
32.3
High Heat - 460V B64-798
20.8 21.4
B64-804 B64-810 B64-816
23
32.3
Heat Pumps 11 EER/3.3 COP, Three-Phase, 7-1/2 & 10 Ton, R410A • Two-stage energy-efficient compressor with internal relief valve • High-capacity, steel-cased bi-flow filter-drier • High & low-pressure switches • High-efficiency copper tube/aluminum fin coil
• Brass liquid and suction line service valves mounted at a 90° angle with sweat connections and service ports • Temperature-terminated defrost control • Contactor with lug connections WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
BtuH Heating Input
Min. Circuit Amps
Max. Fuse Size
Order #
Mfg. #
Nom. Tons BtuH Cooling
Liquid Conn. Suction Fitting Width
Height
Depth
Wt. Lbs.
208/230V B60-950
DZ11TA0903 7-1/2 DZ11TA1203 10 DZ11TA0904 7-1/2 DZ11TA1204 10
93,000
82,000
39.2
60 70 30 35
5/8" 5/8" 5/8" 5/8"
1-3/8" 1-3/8" 1-3/8" 1-3/8"
35-1/2" 35-1/2" 35-1/2" 35-1/2"
41-1/2" 41-1/2" 41-1/2" 41-1/2"
35-1/2" 35-1/2" 35-1/2" 35-1/2"
355 375 355 370
B60-952 460V B60-951 B60-953
115,000 100,000 46.4
93,000
82,000
18.5
115,000 100,000 22.0
Air Conditioning Condensing Units 13 SEER, Three-Phase, 3 To 5 Ton, R410A
• Energy-efficient compressor • Factory-installed filter-drier
• Top and side maintenance access • Steel louver coil guard
• Copper tube enhanced aluminum fin coil • Complies with ASHRAE Standard 90.1 • Service valves with sweat connections and easy access gauge ports
• Note: * 7/8" to 1-1/8" adapter required for suction line connection on 4T and 5T units. Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Min. Circuit Amps
Order #
Mfg. #
Nom. Tons
BtuH Cooling
Max. Fuse Size Liquid Conn.
Suction Fitting Width
Height
Depth
Wt. Lbs.
208/230V B74-084
DX13SA0363 3 DX13SA0483 4 DX13SA0603 5 DX13SA0364 3 DX13SA0484 4 DX13SA0604 5
36,000 48,000 60,000 36,000 48,000 60,000
14.1 17.6 21.3
20 30 35 15 15 15
3/8" 3/8" 3/8" 3/8" 3/8" 3/8"
3/4"
29" 29"
28-3/4" 36-1/4" 38-1/4" 28-3/4" 36-1/4" 38-1/4"
29" 29"
196 190 301 196 189 301
B74-085 B74-111 460V B78-971 B74-086 B74-112
1-1/8" * 1-1/8" *
35-1/2"
35-1/2"
7.9 8.4
3/4"
29" 29"
29" 29"
1-1/8" * 1-1/8" *
10.6
35-1/2"
35-1/2"
757
JohnstoneSupply.com
Made with FlippingBook Annual report maker