©Johnstone Supply eCatalog 216
HVAC CONTROLS Gas Ignition Controls
Universal Intermittent Spark Ignition Control • Microprocessor-based ignition control
• LED diagnostic indicator Specifications: • Electrical rating: 24VAC • Flame out recognition time: 8 Sec.
• For use in natural and LP gas applications • Works with single rod or dual rod remote sensor • Provides ignition, proof of ignition and precise timing
Each
Order # Mfg. #
Description
L51-064 50D50U-843
Intermittent Pilot/Direct Spark Ignition Module
389.00
Key
Reset Time
Retries
Prepurge
Safety Time 90 Seconds 90 Seconds 30 Seconds 30 Seconds 60 Seconds
Key
Reset Time
Retries
Prepurge
Safety Time 60 Seconds 15 Seconds Continuous 4 Seconds 4 Seconds
A B C D E
300 Seconds — 300 Seconds — 300 Seconds — 300 Seconds — 300 Seconds 2
—
F
300 Seconds 2 300 Seconds —
30 Seconds
30 Seconds
G H
—
—
—
—
30 Seconds
30 Seconds
I
300 Seconds — 300 Seconds —
—
—
J
30 Seconds
Universal Intermittent Pilot Control • Replacement for over 400 Honeywell (including S8610U1003), Robertshaw, Johnson Controls and UTEC (HSC) intermittent pilot ignition controls • Used for gas-fired furnaces, boilers and other heating equipment • Field-selectable prepurge and ignition trial timings • LED flame strength indicator • Diagnostic LED for easy troubleshooting • EnviraCOM communications port • 100% pilot gas shutoff if pilot fails to light
• Ignition trial/delay sequence repeats until appliance lights or call for heat is removed; eliminates nuisance lockouts • One model suitable for use with natural or LP gas • Includes remote reset and automatic vent damper plug • Used in systems with combination ignitor sensor (single rod or sense) or separate ignitor and sensor (dual rod or remote sense) • Includes cable adapters to allow field replacement of both Honeywell and competitive controls without replacing existing cable
Each
Order # Mfg. #
Description
L37-808 S8610U3009
Control Module
355.00
36" Ignition Cable Assembly • For use with the S86/S87 family
• A right angle boot on the ignitor end and a straight boot on the module end
Each
Order # Mfg. #
Description
L45-645 392125-2
36" Ignition Cable Assembly
135.00
DSI Furnace Control Boards • DSI Control board to control gas valve, blower, indoor motors, spark ignitor • Monitors timing, trial for ignition, flame sensing and lockout
• Microprocessor-based, 100% lockout safety feature • Compatible with LP or Natural Gas WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
A
B
Each
Fig. Order #
Mfg. #
Ignition Trial Time Ignition Trials
Lockout Timing Prepurge Period For Use With
Description
L45-903
A
ICM291 5 + 2 Seconds Every 20 seconds for 15 min
Manual Reset 45 seconds OEM Replacement for Carrier: LH33WP003, LH33WP003A
Furnace Control Board
545.00
L45-904
ICM292 7 Seconds
Two groups of two 1 hour
30 seconds OEM Replacement for Rheem: 62-24140-04 Furnace Control Board
415.00
B
372
©2023 Johnstone Supply, LLC
Made with FlippingBook Annual report maker