HVAC CONTROLS Fan Controls
Fan Blower Controls • Controls the circulating fan in heat pump, air conditioning and forced air systems • Timer continues to run the fan at the end of the heating/cooling cycle, thereby purging ducts of residual air and increasing system efficiency
Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
A
B
Switch Action Solid State
Secondary Voltage
Each
Fig. Order #
Mfg. #
OEM Replacement for
Control Action Time Delay
Volts
B13-627
A
ICM253B Field Controls: 46144700; Gemline:1C216; Mars: 32393
18-30 VAC OFF Delay OFF = 12 to 390 Sec.
18 to 30VAC 18 to 30VAC
65.00
B13-628
ICM255C Watsco:5893;Bard:8201-056;Mars:32574;Rheem:42-22515-01,42-22515-02,42 22515-03;SnyderGeneral/ICP:1395336
Relay 18-30 VAC ON Delay/ OFF Delay
ON = 1 Sec., OFF = 60 Sec.
65.00
B
Furnace Control Module — Lennox • Direct replacement for OEM control boards • Controls inducer fan motor, blower fan and monitors limit switches • Functions with all 24VAC thermostats
• Microprocessor based WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Each
Order #
Mfg. #
OEM Replacement for
Switch Action Primary Voltage Secondary Voltage Time Delay
Volts
L45-172
ICM289 Lennox: Replaces all BCC1, BCC2 & BCC3 Control Boards Including 48K98 & 45K48
Relay
120 VAC
18-30 VAC
COOL BLOWER ON: 1 sec., COOL BLOWER OFF: 1 sec., HEAT BLOWER ON: 45 sec., HEAT BLOWER OFF: 90,150, 210 or 270sec.
24 and 120VAC
369.00
Fan Control Centers • Provides low voltage control of line voltage fan motors and auxiliary circuits in heating, cooling or heating/cooling circuits • Provides overload protection for transformer • Mounts on standard 4" x 4" junction box
• Includes relay enclosure Specifications:
• F/L Amps @ 120V/240V: 12A/6.9A • LR Amps @ 120V/240V: 72A/41.4A
Each
Order # Mfg. #
Switch Action
VA Rating
Primary Voltage
Secondary Voltage
Relay
L37-138
R8239A1052 SPDT
40 50
120
26.5 26.5
R8222B R8222D
179.00 255.00
L40-349 R8239B1076 DPDT
120/208/240
Furnace Control Module-Carrier • Controls gas valve, ignitor, blower motor, inducer, humidifier and air cleaner • Microprocessor precision • Twinning compatible with another ICM2807 control
• Reverse polarity detection • Secondary brownout voltage protection • Diagnostic LEDs Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Each
Order #
Mfg. #
OEM Replacement for
Switch Action
Primary Voltage
Secondary Voltage
Volts
L47-029
ICM2807 Carrier: HK42FZ017
Relay
120 VAC
18-30 VAC
24 and 120VAC
705.00