©Johnstone Supply eCatalog 216
HVAC CONTROLS Heat Pump Controls
Demand Defrost Control Kit • Demand defrost algorithm “self-calibrates” to the heat pump system • LED diagnostic display • Compressor short-cycle protection • Dipswitch-selectable defrost termination temperature (50/60/70/80ºF)
• Replaceable ambient and coil temperature sensors • Includes high- and low-pressure switch inputs with multi-strike lockouts for additional compressor protection WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Each
Order #
Mfg. #
Volts
OEM Replacement for
B19-026
47D43-811
24 VAC
Rheem
115.00
Universal Heat Pump Defrost Control • Replaces virtually all single stage defrost controls • Selectable demand or timed defrost
• Access set up and diagnostic menus from any orientation • Brown out and short cycle protection WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• Universal mounting with rotating display • Preconfigured for major OEM brands • Integrated indoor thermostat
Each
Order #
Mfg. #
Volts
L47-933
47D01U-843
24 VAC
345.00
Universal Heat Pump Defrost Control • Defrost control for single stage on/off heat pumps • Provides control of the outdoor equipment; compressor contactor, reversing valve,
and outdoor fan in response to thermostat requests and air and coil temperatures • Replaces more than 260 OEM defrost controls
Each
Order # Mfg. #
Volts
B21-262 DB7110U1000/U 24 VAC
299.00
BC Blower Control • Increase heating efficiency by delaying the ON and OFF cycle of blower fan • Control voltage: 24 VAC
• Relay contacts: SPST • Blower on time: 0-240 seconds adjustable • Blower off time: 0-240 seconds adjustable
Each
Order # Mfg. # L47-609 BC7070
105.00
Fan Control Centers • OEM replacement control circuit boards for circulating fans in heat pumps, air conditioning
• ON delay allows air to reach the proper comfort level prior to energizing fan • Input voltage: 18 to 30VAC Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
units and forced-air systems • Dual function fan delay timer • OFF delay purges ducts of residual air
Switch Action
Primary Voltage
Secondary Voltage
Each
Order #
Mfg. #
OEM Replacement for
Time Delay
Volts
L38-651
ICM271C Robertshaw: 695-100; Carrier: CES0110017,
Relay 120 VAC 18-30 VAC HEAT BLOWER ON: 75 sec., HEAT BLOWER OFF: 105 sec., COOL BLOW ER OFF; 90 sec. Relay 120 VAC 18-30 VAC HEAT BLOWER ON: 60sec., HEAT BLOWER OFF: 60-240sec., COOL BLOWER OFF: 90 sec.
18-30 VAC 179.00
CES0110018; Carrier/BDP: HH84AA010, HH84AA011, HH84AA012, HH84AA013, HH84AA020, P771-7002, 302075-3
L38-652
ICM275C Robertshaw: 695-101; Carrier: CES11019, HH84AA001, HH84AA003, HH84AA005, HH84AA009, HH84AA014, HH84AA015, HH84AA021
18-30 VAC 209.00
L43-835
ICM277C Goodman: B1370735S
Relay — 18-30 VAC ON: 7 sec., OFF: 65 sec.
18-30 VAC 155.00
326
©2023 Johnstone Supply, LLC
Made with FlippingBook Annual report maker