CONDENSER FAN MOTORS 42 Frame Permanent Split Capacitor

Help Johnstone Supply Help You With Your Motor Replacement Needs Provide the following information for more accurate motor replacement: 1. Before dismantling, scratch an arrow on the case of the motor indicating direction of rotation. 2. Note the voltage. Often, it is not indicated on the nameplate. 3. Note the number of speeds. 4. Note the type of motor: Permanent split capacitor (PSC) or shaded pole. 5. Note the shaft diameter. 6. Note the capacitor size if a PSC motor. 7. Provide all nameplate data: a) Horsepower b) Amps c) RPM

Condenser Fan Motors PSC, 42 Frame, Open Air Over Applications: • For replacing horizontal, base mounted condenser fan motors

Features: • Automatic thermal protector, sleeve bearing • Continuous duty, air over

Shaft Diam.

Shaft Length Rot.

Bearing Type

Each

Order # Mfg. # S81-169 721P S81-168 722P

Diam.

HP

Volts

RPM Speeds F/L Amps Efficiency

“A” Dim.

Wt. Lbs.

5" 5"

1/10

115/230 1550 1 115/230 1550 1

2.60 2.70

40% 1/2" 54% 1/2"

2-5/8" 2-7/16"

CWLE 3-13/16" SAB 9.0 CWLE 3-13/16" SAB 11.0

825.00 799.00

1/6

Evergreen ® OM Outdoor Condenser Fan Motors ECM, 48 Frame, Totally Enclosed Air Over • 80% efficient • 2-speed taps; one for 1100 RPM and one for 850 RPM. Replaces a 6-pole PSC and an 8-pole PSC • Electrically reversible

Bearing Type

Each

Order # Mfg. #

Diam.

HP

Volts

RPM Speeds

F/L Amps Efficiency Shaft Diam. Shaft Length Rot.

Wt. Lbs.

For Residential Use S82-490 6303 5-5/8”

1/3 1/5

208-230 1100/850 2 208-230 1100/850 2

3.50 2.80

80% 1/2” 80% 1/2”

3” 3”

Rev. Rev.

Ball Ball

13.0 10.0

685.00 675.00

S82-489 6301

5-5/8”

RESCUE EcoTech ® Condenser Fan Motors ECM, 48 or 56 Frame, Totally Enclosed Air Over • S82-764 and S83-361 are 48 frame and replace 6- and 8-pole motors

• ECM technology lowers energy usage, especially at partial output and integrates easily into existing air-cooled condenser designs Specifications: • S82-764 mounts vertical, shaft down • S83-361 mounts vertical, shaft up

• Line-voltage starting motor with 2 speeds • Second speed adjustment use a 24V speed tap • Rotation adjustment use a 24V rotation tap • High 60°C max ambient operating temperature • S83-359 and S83-360 are 56 frame for use in commercial refrigeration condensers

A

B

Shaft Length

Bearing Type

Each

Fig. Order # Mfg. #

Diam.

HP

Volts

RPM F/L Amps Efficiency Shaft Diam.

Rot.

“A” Dim.

Wt. Lbs.

48 Frame A S82-764 56 Frame B A S83-361

5561EO 5-5/8" 5562EO 5-5/8"

1/3 1/3

208-230 1200 208-230 1200

2.50 2.50

Up to 75% 1/2" Up to 75% 1/2"

4-1/2" 4-1/2"

Rev. Rev.

5.625" 6.366"

Ball Ball

11.0 10.0

829.00 825.00

S83-359 6361EO 6-1/2" S83-360 6362EO 6-1/2"

2-1/2 2-1/4

208-230 300-1200 6.50-5.80 85% 5/8"

3.35" 3.35"

Rev. Rev.

— Ball — Ball

45.0 56.0

3299.00 3499.00

B

460

300-1200 2.70

85% 5/8"

28

©2023 Johnstone Supply, LLC