©Johnstone Supply eCatalog 216
HVAC EQUIPMENT Boilers
Crown Oil Furnaces • Heavy gauge drum style heat exchanger • Ceramic fiber combustion chamber • 22-gauge powder coated cabinet • Limited lifetime warranty on heat exchanger • 5-year parts warranty Outfitted with Beckett AFG model oil burner
• Multi-speed direct drive blower motor which can be removed for cleaning Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Note: L95-821 is Energy Star qualified and uses an ECM blower motor
Heating Capacity MBH Flue Diam.
Order #
Mfg. #
Gas Type
AFUE
Width
Height
Depth
Wt. Lbs.
Energy Star
L95-820 L95-821 L95-822 L95-823 L95-824
VCSHB60-90ABP Oil VCSHB60-90ABT Oil VCLBF68-112DBP Oil VCLBR68-112DBP Oil VCHC68-96CBP Oil
85.0% 85.0% 85.0% 85.0% 85.0%
90,000 90,000 114,000 114,000 97,000
5" 5" 6" 6" 6"
21" 21"
45" 45"
30" 30" 47" 47"
270 270 300 300 280
—
Y
22-1/4" 22-1/4" 22-1/4"
41-1/2" 41-1/2" 61-1/4"
— — —
22-1/4"
Raptor Firetube Stainless Steel Condensing Gas Hot Water Boilers
• Stainless steel condensing hot water boiler • Stainless steel fire tube heat exchanger • Wall mounted • Natural gas, field convertible to LP gas • Fully modulating with 10:1 turndown ratio • Honeywell SOLA control with touch screen user interface
• Vent adapter allows for venting with CPVC/ PVC or single wall polypropylene venting Specifications: • If flue diameter chart information shows more than one size, see manual for conversion instructions Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Heating Capacity MBH
AHRI Net Ratings MBH Flue Diam.
Order #
Mfg. #
BtuH Input
Gas Type
AFUE
Width
Height
Depth
Wt. Lbs.
Energy Star
L94-188 L94-189 L94-190 L94-191 L94-192 L94-152 L94-153
RPTR085HNZ2SU 85,000
Natural or LP 96.0% 79,000
69,000 89,000
2” or 3” 2” or 3”
19-13/16” 19-13/16” 19-13/16” 19-13/16” 19-13/16”
33-5/16” 33-5/16” 33-5/16” 33-5/16” 33-5/16”
20” 20” 20” 21” 21”
110 115 120 135 145 135 145
Y Y Y Y Y
RPTR110HNZ2SU 110,000 Natural or LP 96.0% 102,000 RPTR155HNZ2SU 155,000 Natural or LP 95.0% 145,000 RPTR205HNZ2SU 205,000 Natural or LP 95.0% 190,000 RPTR270HNZ2SU 270,000 Natural or LP 95.0% 251,000 RPTR320HNZ1SU 320,000 Natural or LP 95.0% 304,000 RPTR399HNZ1SU 399,000 Natural or LP 95.0% 379,000
126,000 3” 165,000 3” 218,000 3” 264,000 4” 330,000 4”
23” 23”
45.28” 45.28”
22.4” 22.4”
— —
Phantom II Boilers Gas Fired Condensing, Stainless Steel, Hot Water Boiler
• Stainless steel condensing hot water boiler • Stainless steel water tube heat exchanger • Wall mounted • Gas adaptive combustion system • Field convertible to LP gas • Fully modulating with 10:1 turndown ratio • Push button user interface • Vent adapter allows for venting with CPVC/ PVC or single wall polypropylene
• Boiler circulator included • Approved for installation to 2,000 ft elevation with NG or LP gas Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Heating Ca pacity MBH
AHRI Net Ratings MBH Flue Diam.
Order #
Mfg. #
BtuH Input
Gas Type AFUE
Width
Height
Depth
Wt. Lbs.
Energy Star
Sea Level L60-666
PHTM2120HNG1SUA 120,000 NG or LP 95.0% 112,000 97,000 PHTM2150HNG1HUA 150,000 NG or LP 95.0% 141,000 123,000 2” PHTM2180HNG1HUA 180,000 NG or LP 95.0% 169,000 147,000 2” 2”
18” 18” 18”
29.8” 29.8” 29.8”
16.3” 20.4” 20.4”
76
Y Y Y
L60-667 L60-668
103 103
548
©2023 Johnstone Supply, LLC
Made with FlippingBook Annual report maker