©Johnstone Supply eCatalog 216
HVAC EQUIPMENT Coleman Commercial Split Systems
Air Conditioning Condensing Units LX Series, 13 SEER, Three-Phase, 2-1/2 to 5 Ton, R410A • Aluminum microchannel tubing coil and enhanced aluminum fins
• Secured service valves • Easy service access • Compressors are protected against high pressure and temperature • 2-1/2, 3 & 3-1/2 Ton units have Copeland compressors Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• Factory installed filter-drier • Lower operating sound level • Top discharge of warm air • Stamped steel coil guard • Low maintenance due to long life of motor bearings
Order #
Mfg. #
Nom. Tons
Min. Circuit Amps Max. Fuse Size Liquid Conn.
Suction Fitting Width
Height
Depth
Wt. Lbs.
208/230V B61-256
TCD30B32S 2-1/2
11.91 14.34 15.29
20 20 25 30 35 15 15 15 15 15
3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8"
3/4" 3/4" 7/8" 7/8" 3/4" 3/4" 7/8" 7/8"
29-1/4" 29-1/4" 35-1/4" 35-1/4" 29-1/4" 29-1/4" 35-1/4" 31-3/4" 34-1/4" 38"
30"
29-1/4" 29-1/4" 31-3/4" 31-3/4" 34-1/4" 29-1/4" 29-1/4" 31-3/4" 31-3/4" 34-1/4"
140 160 200 200 205 140 160 200 200 205
B61-258 B61-260 B79-354 B79-356 460V B61-257 B61-259 B61-261 B79-355 B79-357
TCD36B32S 3
36-1/4" 33-1/4" 33-1/4" 36-1/4" 36-1/4" 33-1/4" 33-1/4" 36-1/4" 30"
TCD42B32S 3-1/2
TCD48B31S 4 TCD60B31S 5
18.4 21.2
1-1/8"
TCD30B42S 2-1/2
5.67 7.85 7.68
TCD36B42S 3
TCD42B42S 3-1/2
TCD48B41S 4 TCD60B41S 5
8.4
10.3
1-1/8"
Horizontal Discharge Air Conditioning Condensing Units 13 SEER, Three-Phase, 3 to 4 Ton, R410A • Industry leading microchannel coil technology • Compact “slim-line” design allows units to be stacked • High efficiency scroll compressor and swept wing fan • Compresors are protected against high pressure and temperature • Heavy-gauge steel cabinet and tubular base rail for support • Permanently lubricated motor bearings • Secured service valve • Factory supplied filter-drier • High and low pressure switch • Accumulator and crankcase heater in all sizes • 6" clearance in either direction WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Min. Circuit Amps
Order #
Mfg. #
Nom. Tons
BtuH Cooling
Max. Fuse Size Liquid Conn.
Suction Fitting Width
Height
Depth
Wt. Lbs.
208/230V B91-946
TCHD36S43S3 3 TCHD48S43S3 4
36,000 48,000
17.5 21.5
30 35
3/8" 3/8"
3/4" 7/8"
45" 45"
37-1/4" 43-1/4"
20" 20"
215 240
B91-947
Air Handlers NH Series, Three-Phase, 7-1/2 to 15 Ton, R410A • Horizontal or vertical position • Designed with two distinct modules to provide maximum application flexibility • Blower module includes blower wheels with factory mounted motor and drives • The coil module includes direct expansion coils • Air pressurized and leak tested air handler coil
• Available in 4 pipe configuration • Permanently lubricated ball bearings • Overload relays factory installed • Factory installed TXV's • Optional base sections can be used to elevate unit above floor Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Order #
Mfg. #
Nom. Tons
Liquid Conn.
Suction Fitting
Width
Height
Depth
Wt. Lbs.
B90-387 B74-006 B90-389
NH-07C00BSAAA2 7-1/2 NH-07C00CSAAA2 7-1/2 NH-15C00DSAAA2 15
5/8" 5/8" 7/8"
1-1/8” 1-1/8” 1-5/8”
30” 30” 33”
65” 65” 75”
56” 56”
526 526 796
74-1/2”
804
©2023 Johnstone Supply, LLC
Made with FlippingBook Annual report maker