HVAC EQUIPMENT Coleman Commercial Split Systems

Air Conditioning Condensing Units LX Series, 13 SEER, Three-Phase, 2-1/2 to 5 Ton, R410A • Aluminum microchannel tubing coil and enhanced aluminum fins

• Secured service valves • Easy service access • Compressors are protected against high pressure and temperature • 2-1/2, 3 & 3-1/2 Ton units have Copeland compressors Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

• Factory installed filter-drier • Lower operating sound level • Top discharge of warm air • Stamped steel coil guard • Low maintenance due to long life of motor bearings

Order #

Mfg. #

Nom. Tons

Min. Circuit Amps Max. Fuse Size Liquid Conn.

Suction Fitting Width

Height

Depth

Wt. Lbs.

208/230V B61-256

TCD30B32S 2-1/2

11.91 14.34 15.29

20 20 25 30 35 15 15 15 15 15

3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8"

3/4" 3/4" 7/8" 7/8" 3/4" 3/4" 7/8" 7/8"

29-1/4" 29-1/4" 35-1/4" 35-1/4" 29-1/4" 29-1/4" 35-1/4" 31-3/4" 34-1/4" 38"

30"

29-1/4" 29-1/4" 31-3/4" 31-3/4" 34-1/4" 29-1/4" 29-1/4" 31-3/4" 31-3/4" 34-1/4"

140 160 200 200 205 140 160 200 200 205

B61-258 B61-260 B79-354 B79-356 460V B61-257 B61-259 B61-261 B79-355 B79-357

TCD36B32S 3

36-1/4" 33-1/4" 33-1/4" 36-1/4" 36-1/4" 33-1/4" 33-1/4" 36-1/4" 30"

TCD42B32S 3-1/2

TCD48B31S 4 TCD60B31S 5

18.4 21.2

1-1/8"

TCD30B42S 2-1/2

5.67 7.85 7.68

TCD36B42S 3

TCD42B42S 3-1/2

TCD48B41S 4 TCD60B41S 5

8.4

10.3

1-1/8"

Horizontal Discharge Air Conditioning Condensing Units 13 SEER, Three-Phase, 3 to 4 Ton, R410A • Industry leading microchannel coil technology • Compact “slim-line” design allows units to be stacked • High efficiency scroll compressor and swept wing fan • Compresors are protected against high pressure and temperature • Heavy-gauge steel cabinet and tubular base rail for support • Permanently lubricated motor bearings • Secured service valve • Factory supplied filter-drier • High and low pressure switch • Accumulator and crankcase heater in all sizes • 6" clearance in either direction WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Min. Circuit Amps

Order #

Mfg. #

Nom. Tons

BtuH Cooling

Max. Fuse Size Liquid Conn.

Suction Fitting Width

Height

Depth

Wt. Lbs.

208/230V B91-946

TCHD36S43S3 3 TCHD48S43S3 4

36,000 48,000

17.5 21.5

30 35

3/8" 3/8"

3/4" 7/8"

45" 45"

37-1/4" 43-1/4"

20" 20"

215 240

B91-947

Air Handlers NH Series, Three-Phase, 7-1/2 to 15 Ton, R410A • Horizontal or vertical position • Designed with two distinct modules to provide maximum application flexibility • Blower module includes blower wheels with factory mounted motor and drives • The coil module includes direct expansion coils • Air pressurized and leak tested air handler coil

• Available in 4 pipe configuration • Permanently lubricated ball bearings • Overload relays factory installed • Factory installed TXV's • Optional base sections can be used to elevate unit above floor Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Order #

Mfg. #

Nom. Tons

Liquid Conn.

Suction Fitting

Width

Height

Depth

Wt. Lbs.

B90-387 B74-006 B90-389

NH-07C00BSAAA2 7-1/2 NH-07C00CSAAA2 7-1/2 NH-15C00DSAAA2 15

5/8" 5/8" 7/8"

1-1/8” 1-1/8” 1-5/8”

30” 30” 33”

65” 65” 75”

56” 56”

526 526 796

74-1/2”

804

©2023 Johnstone Supply, LLC