©Johnstone Supply eCatalog 216
HVAC EQUIPMENT Coleman Residential Packaged Units
Single Packaged Heat Pumps LX Series, 14 & 16 SEER, Single-Phase, 2 To 5 Ton, R410A • High pressure switch • Standard ECM indoor fan motor
• Grooved cooper tubes with enhanced Aluminum fin; indoor coils use tin-coated copper tubing with Aluminum fins • Internal compressor protection (temperature and pressure) • Convertible airflow design • Field installed electric heaters available • 208/230V Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• Top discharge condenser air design • Full perimeter, removable base rails • Slide-out blower assembly • Easily field convertible from side to bottom discharge • Stamped slotted coil guard to provide impact protection against small objects
BtuH Heating Input
Min. Circuit Amps
Order #
Mfg. #
Nom. Tons BtuH Cooling
HSPF
COP
Nom. CFM
Width
Height
Depth
Wt. Lbs.
14 SEER B64-158
PHE4A2424 2
25,000 29,600 35,800 42,000 48,000 59,500 23,500 47,500 57,500
23,600 28,200 34,800 39,000 46,500 56,500 22,000 47,400 57,200
8.0 8.0 8.0 8.0 8.0 8.0 8.2 8.2 8.2
3.7 3.7 3.6 3.6 3.7 3.6 3.7 3.6 3.6
780 950
18.6 20.5 23.9 27.0 30.0 36.5 19.1 33.6 42.3
35-3/4" 35-3/4" 45-3/4" 45-3/4" 45-3/4" 45-3/4" 35-3/4" 45-3/4" 45-3/4"
44" 45" 47" 47" 53" 55" 47" 53" 55"
51-1/4" 51-1/4" 51-1/4" 51-1/4" 51-1/4" 51-1/4" 51-1/4" 51-1/4" 51-1/4"
330 355 420 436 479 485 377 496 523
B64-159 B64-160 B64-161 B64-162 B64-163
PHE4A3024 2-1/2
PHE4B3624 3
1,150 1,350 1,500 1,850
PHE4B4224 3-1/2
PHE4B4824 4 PHE4B6024 5 PHE6A2421 2 PHE6B4821 4 PHE6B6021 5
16 SEER B79-383
800
B79-387 B79-388
1,600 1,800
Dual Fuel Packaged Heat Pumps LX Series, 14 & 16 SEER, Single-Phase, Single-Stage, 2 To 5 Ton, R410A • Full perimeter base rail • Top discharge • Condenser coil grille • Protected compressor against high pressure and temperature • High pressure switch • Stainless-steel heat exchanger • Post purge induced draft combustion
• Standarad ECM fan motor • Convertible airflow design • Aluminum fin construction and grooved copper tubes • Low operating sound level • Condensate drain pan • 208/230V Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• Spark to burner ignition • Multi port in-shot burner
BtuH Cooling
BtuH Heat ing Input
Min. Circuit Amps
Order #
Mfg. #
Nom. Tons
HSPF
COP
Nom. CFM
Width
Height
Depth
Wt. Lbs.
Energy Star
14 SEER B64-400
PHG4A240752X4 2 PHG4A300752X4 2-1/2 PHG4B361002X4 3 PHG4B420652X4 3-1/2 PHG4B421002X4 3-1/2 PHG4B481002X4 4 PHG4B481252X4 4 PHG4B601252X4 5
25,000 75,000 8.0 29,600 75,000 8.0 35,800 100,000 8.0 42,000 65,000 8.0 42,000 100,000 8.0 48,000 100,000 8.0 48,000 125,000 8.0 59,500 125,000 8.0
4.5
780 950
17.4 19.3 23.9 27.0 27.0 30.0 30.0 36.5
35-3/4” 35-3/4” 45-3/4” 45-3/4” 45-3/4” 45-3/4” 45-3/4” 45-3/4”
44” 45” 47” 47” 47” 53” 53” 55”
51-1/4” 51-1/4” 51-1/4” 51-1/4” 51-1/4” 51-1/4” 51-1/4” 51-1/4”
357 416 477 497 499 542 544 550
— — — — — — — —
B64-401 B64-402 B64-403 B64-404 B64-405 B64-406 B64-407
5.04 4.95 5.08 5.08 5.02 5.02 4.96
1,150 1,350 1,350 1,500 1,500 1,850
16 SEER B60-887
PHG6B600652X1 5
57,500 65,000 8.2
3.6
1,800
44.7
45-3/4”
55”
51-1/4”
577
Y
Hundreds of thousands of OEM solutions at your fingertips For all of your AC needs supporting you from installation and beyond
798
©2023 Johnstone Supply, LLC
Made with FlippingBook Annual report maker