HVAC EQUIPMENT Coleman Air Conditioning Condensing Units

Air Conditioning Condensing Units LX Series, 17 SEER, Single-Phase, 1-1/2 To 5 Ton, R410A

• Microchannel aluminum coils • Coated steel wire fan guard • ECM fan motor • High pressure relief valve and temperature sensor • High and low pressure switches • Factory installed liquid line filter-drier • Low operating sound levels • Diagonal base valves

• Adapter fitting required for 1-1/8 line set • 208/230V Applications: • Product not suitable for all regions Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Note: Installation must meet all Federal, State, and Local guidelines

Min. Circuit Amps

Max. Fuse Size

Order #

Mfg. #

Nom. Tons BtuH Cooling

Liquid Conn.

Suction Fitting Width

Height

Depth

Wt. Lbs.

OEM TXV B19-657 B20-469 B19-657 B19-659

B78-418 B78-419 B78-420 B78-422

CC7B2421S 2

24,000 30,000 36,000 48,000

16.4 18.8 22.0 25.9

25 30 35 40

3/8" 3/8" 3/8" 3/8"

3/4” 3/4” 3/4” 7/8”

29-1/4” 35-1/4” 35-1/4”

30”

29-1/4” 31-3/4” 31-3/4” 34-1/4”

150 165 175 220

CC7B3021S 2-1/2

36-1/4” 36-1/4” 39-1/2”

CC7B3621S 3 CC7B4821S 4

38”

Air Conditioning Condensing Units Echelon™ 19 SEER, Single-Phase, Two-Stage, 2 To 5 Ton, R410A • 2-piece steel extruded louver coil guard protects the tube-in-fin coil • 2-speed protected scroll compressor • WhisperDrive™ System

• Advanced system control • Factory or field installed TXV • Communication capable • Adapter fitting required for 1-1/8" line set • 208/230V Applications: • Product not suitable for all regions Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Note: Installation must meet all Federal, State, and Local guidelines

• ECM fan motor • Swept wing fan • Composite base pan • Aluminum fin and copper tube outdoor coil • Factory installed filter-drier • Climate Connect™ providing pre-configured operating profiles • Easy service access

Min. Circuit Amps

Max. Fuse Size

Order #

Mfg. #

Nom. Tons BtuH Cooling

Liquid Conn. Suction Fitting Width

Height

Depth

Wt. Lbs.

OEM TXV B20-469 B19-657 B19-659 B19-659

B60-665 B60-666 B60-667 B60-668

AC19B2421S 2 AC19B3621S 3 AC19B4821S 4 AC19B6021S 5

24,000 36,000 48,000 60,000

15.3 21.4 28.2 31.4

25 35 45 50

3/8" 3/8" 3/8" 3/8"

3/4" 3/4" 7/8"

38-1/4" 38-1/4" 38-1/4" 38-1/4"

40-1/4" 46-1/2" 46-1/2" 46-1/2"

34-1/2" 34-1/2" 34-1/2" 34-1/2"

195 265 295 295

1-1/8"*

Air Conditioning Condensing Units Echelon™ 20 SEER, Single-Phase, Modulating, 2 To 5 Ton, R410A

• Copper tube and aluminum fin coil • Variable capacity (inverter driven) • Inverter drive scroll compressor • Copper or stainless steel filter-drier • Composite base pan • Swept-wing fan with ECM fan motor • Slotted 2-piece coil guard • Communicating only • Outdoor main control with Charge View™ • Power conditioning chokes • 24VAC transformer

• Removable fan guard • Hx thermostat • Adapter fitting required for 1-1/8" line set • 208/230V Applications: • Product not suitable for all regions Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Note: Installation must meet all Federal, State, and Local guidelines

Min. Circuit Amps

Order #

Mfg. #

Nom. Tons

BtuH Cooling

Max. Fuse Size Liquid Conn.

Suction Fitting Width

Height

Depth

Wt. Lbs.

B79-685 B79-686 B79-687 B79-688

AC21B2421S 2 AC21B3621S 3 AC21B4821S 4 AC21B6021S 5

24,000 36,000 48,000 60,000

17.4 25.7 28.6 33.9

30 40 45 50

3/8" 3/8" 3/8" 3/8"

3/4" 3/4" 7/8" 7/8"

32" 32"

40-1/4" 40-1/4" 43-1/4" 46-1/2"

35-1/2" 35-1/2" 38-1/4" 38-1/4"

194 205 264 270

34-1/2" 34-1/2"

787

JohnstoneSupply.com

Made with FlippingBook Annual report maker