©Johnstone Supply eCatalog 216

HVAC EQUIPMENT Coleman Air Conditioning Condensing Units

Horizontal Discharge Air Conditioning Condensing Units 13 SEER, Single-Phase, 1-1/2 to 5 Tons, R410A

• Industry leading microchannel coil technology • Compact ™slim-line™ design allows units to be stacked • High efficiency scroll compressor and swept wing fan for quiet operation • Compressors are protected against high pressure and temperature • Heavy-gauge steel cabinet and tubular base rail for support • Secured service valve • Factory supplied filter-drier

• Accumulator and crankcase heater • Up to 200' line set out of the box • 6" clearance in either direction • 208/230V Applications: • Product not suitable for all regions Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Note: Installation must meet all Federal, State, and Local guidelines

Min. Circuit Amps

Max. Fuse Size

Order #

Mfg. #

Nom. Tons BtuH Cooling

Liquid Conn. Suction Fitting Width

Height

Depth

Wt. Lbs.

OEM TXV B17-085 B17-085 B17-086 B17-086 B17-088 B17-089

B91-939 B75-666 B91-941 B91-942 B91-943 B91-944

TCHD18S41S3 1-1/2 TCHD24S41S4 2 TCHD30S41S3 2-1/2 TCHD36S41S3 3 TCHD48S41S3 4 TCHD60S41S3 5

18,000 24,000 30,000 36,000 48,000 60,000

11.8 18.3 17.5 23.1 27.1 34.3

20 30 30 40 45 60

3/8" 3/8" 3/8" 3/8" 3/8" 3/8"

3/4” 3/4” 3/4” 3/4” 7/8” 7/8”

37-1/4”

25-1/4” 37-1/4” 37-1/4” 37-1/4” 43-1/4” 43-1/4”

17-1/2”

130 195 195 215 240 250

45” 45” 45” 45” 45”

20” 20” 20” 20” 20”

Air Conditioning Condensing Units LX Series, 14 SEER, Single-Phase, 1-1/2 to 5 Ton, R410A

• High efficiency microchannel aluminum • Stamped steel coil guard for coil protection • High pressure relief valve, temperature sensor & high pressure switch for compressor protection • Factory installed liquid line filter-drier • Top discharge • Low operating sound levels • Adapter fitting required for 1-1/8" line set

• 208/230V Applications: • Product not suitable for all regions Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Note: Installation must meet all Federal, State, and Local guidelines

Min. Circuit Amps

Max. Fuse Size

Order #

Mfg. #

Nom. Tons BtuH Cooling

Liquid Conn. Suction Fitting Width

Height

Depth

Wt. Lbs.

OEM TXV

Southeast & Northern Region Only B61-251 TC4B1822S 1-1/2 18,000

12.7 14.8 18.4 19.6 25.3 25.7 31.7 11.8 14.8 18.4 22.1 25.7 31.7 19.62

20 25 30 30 40 45 50 20 25 30 30 35 45 50

3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8"

3/4" 3/4" 3/4" 3/4" 7/8" 7/8" 3/4" 3/4" 3/4" 3/4" 7/8" 7/8"

24"

30"

24"

125 135 140 145 185 200 205 130 135 140 160 200 200 205

B20-469 B20-469 B19-657 B19-657 B19-659 B19-659 B19-660 B19-657 B20-469 B19-657 B19-657 B19-659 B19-659 B19-660

B61-252 B61-253 B61-254 B61-255 B77-430 B77-431 B62-066 B62-067 B62-068 B77-436 B77-437 B77-438

TC4B2422S 2

24,000 30,000 36,000 42,000 48,000 60,000 24,000 30,000 36,000 42,000 48,000 60,000

29-1/4" 29-1/4" 29-1/4" 29-1/4" 35-1/4"

26-3/4" 26-3/4" 36-1/4" 33-1/4" 36-1/4" 30"

29-1/4" 29-1/4" 29-1/4" 29-1/4" 31-3/4" 34-1/4" 29-1/4" 29-1/4" 29-1/4" 31-3/4" 31-3/4" 31-3/4" 24"

TC4B3022S 2-1/2

TC4B3622S 3

TC4B4222S 3-1/2

TC4B4821S 4 TC4B6021S 5

1-1/8"*

38"

Standard - Southwest Region Only B77-432 TW4B1821S 1-1/2 18,000

24"

33-1/4"

TW4B2422S 2

29-1/4" 29-1/4" 29-1/4" 35-1/4" 35-1/4"

30" 30"

TW4B3022S 2-1/2

TW4B3622S 3

36-1/4" 33-1/4" 33-1/4" 36-1/4"

TW4B4221S 3-1/2

TW4B4821S 4 TW4B6021S 5

1-1/8"*

38"

Horizontal Discharge Air Conditioning Condensing Units 14 SEER, Single-Phase, 2 To 4 Tons, R410A • Industry leading microchannel coil technology • Compact "slim-line" design allows units to be stacked • High efficiency scroll compressor and swept wing fan for quiet operation • Compressors are protected against high pressure and temperature • Heavy-gauge steel cabinet and tubular base rail for support • Secured service valve • Factory supplied filter-drier

• Accumulator and crankcase heater • Up to 200' line set out of the box • 6" clearance in either direction • 208/230V Applications: • Product not suitable for all regions Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Note: Installation must meet all Federal, State, and Local guidelines

Min. Circuit Amps

Max. Fuse Size

Order #

Mfg. #

Nom. Tons BtuH Cooling

Liquid Conn. Suction Fitting Width

Height 37-1/4" 37-1/4" 43-1/4"

Depth

Wt. Lbs.

OEM TXV B19-657 B20-259 B20-259

B60-174 B60-175 B60-176

TCHE24S41S1 2 TCHE36S41S1 3 TCHE48S41S1 4

24,000 36,000 48,000

18.3 19.1 24.6

30 30 40

3/8" 3/8" 3/8"

3/4" 3/4" 7/8"

45" 45" 45"

20" 20" 20"

195 215 240

785

JohnstoneSupply.com

Made with FlippingBook Annual report maker