©Johnstone Supply eCatalog 216

HVAC EQUIPMENT Coleman Heat Pumps

Heat Pumps LX Series, 16 SEER, Single-Phase, 1-1/2 to 5 Ton, R410A

• Aluminum fin and copper tube outdoor coil • Removable 2-piece steel extruded louver coil guard

• Easy service access • Adapter fitting required for 1-1/8" line set • 208/230V Applications: • Product not suitable for all regions Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Note: Installation must meet all Federal, State, and Local guidelines

• 1-Stage scroll compressor • Factory installed filter-drier • TXV controls to all indoor coils • Suction accumulator • Demand defrost • High & low pressure switches • Conventional controls

BtuH Cooling

BtuH Heat ing Input

Min. Circuit Amps

Max. Fuse Size

Suction Fitting

Order #

Mfg. #

Nom. Tons

HSPF

Liquid Conn.

Width

Height

Depth

Wt. Lbs.

OEM TXV B19-657 B19-657 B19-657 B19-658 B19-659 B19-659 B19-660

B61-215 B61-216 B61-217 B61-218 B61-219 B61-220 B61-221

CH6B1821S 1-1/2

18,000 18,000 9.0 24,000 24,000 9.0 30,000 30,000 9.0 36,000 36,000 9.0 42,000 42,000 9.0 48,000 48,000 9.0 60,000 60,000 9.0

14.0 15.5 19.6 22.0 28.7 25.9 32.4

20 25 30 35 45 40 50

3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8"

3/4" 3/4" 3/4" 3/4" 7/8" 7/8"

29-1/4" 35-1/4" 35-1/4" 35-1/4"

36-1/4" 39-1/2" 39-1/2" 39-1/2" 39-1/2"

29-1/4" 31-3/4" 31-3/4" 31-3/4" 31-3/4" 34-1/4" 34-1/4"

136 176 176 223 270 292 304

CH6B2421S 2

CH6B3021S 2-1/2

CH6B3621S 3

CH6B4221S 3-1/2

38" 38" 38"

CH6B4821S 4 CH6B6021S 5

46" 46"

1-1/8"*

Horizontal Discharge Heat Pumps HMH7 Series, 17 SEER, Single-Phase, Modulating, 2 To 5 Ton, R410A • ECM motor • Modulating rotary compressor • Swept wing fan • Aluminum fin and copper tube outdoor coil

Applications: • Product not suitable for all regions Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Note: Installation must meet all Federal, State, and Local guidelines

• Field installed TXVs • Easy service access • 208/230V

BtuH Cooling

BtuH Heat ing Input

Min. Circuit Amps

Max. Fuse Size

Liquid Conn.

Suction Fitting

Order #

Mfg. #

Nom. Tons

HSPF

Width

Height

Depth

Wt. Lbs.

OEM TXV B19-657 B19-659 B19-659 B19-659

B64-413 B64-414 B64-415 B64-416

HMH72B241S 2 HMH72B361S 3 HMH72B481S 4 HMH72B601S 5

22,200 22,000 9 36,000 36,000 10.5 48,000 46,000 9.5 58,500 56,000 10

15 23 36 37

25 35 50 50

3/8" 3/8" 3/8" 3/8"

5/8" 3/4" 7/8" 7/8"

33-7/8" 37-3/8" 37-3/8" 37-3/8"

26-3/8"

12-1/4" 13-3/8" 13-3/8" 13-3/8"

112 148 227 251

33"

54-5/8" 54-5/8"

Heat Pumps Echelon™ 19 SEER, Single-Phase, Two-Stage, 2 To 5 Ton, R410A • Copper tube and aluminum fin coil • WhisperDrive™ System • 2-Stage scroll compressor • Swept-wing fan with ECM fan motor • Composite base pan • Factory installed filter-drier • Climate Connect™ • Hx thermostat • Communications capable • Suction accumulator • Compressor crankase heater • Compressor sound blanket

• Adapter fitting required for 1-1/8" line set • 208/230V Applications: • Product not suitable for all regions Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Note: Installation must meet all Federal, State, and Local guidelines

BtuH Cooling

BtuH Heat ing Input

Min. Circuit Amps

Max. Fuse Size

Liquid Conn.

Suction Fitting

Order #

Mfg. #

Nom. Tons

HSPF

Width

Height

Depth

Wt. Lbs. OEM TXV

B60-669 B60-670 B60-671 B60-672

HC19B2421S 2 HC19B3621S 3 HC19B4821S 4 HC19B6021S 5

24,000 24,000 9.5 36,000 36,000 10 48,000 48,000 9.6 60,000 60,000 9.6

15.3 21.4 28.2 31.4

25 35 45 50

3/8" 3/8" 3/8" 3/8"

3/4" 3/4" 7/8"

31-3/4" 34-1/2" 34-1/2" 34-1/2"

39-1/2" 46-1/2" 46-1/2" 46-1/2"

35-1/4" 38-1/4" 38-1/4" 38-1/4"

176 256 292 304

B19-658 B19-658 B19-659 B19-659

1-1/8" *

783

JohnstoneSupply.com

Made with FlippingBook Annual report maker