HVAC EQUIPMENT Coleman Gas Furnaces
96% AFUE Multi-Position Gas Furnaces TM9V Series, Two-Stage, Variable-Speed, ECM, 33" Height • Communicating control • Multi-position upflow, horizontal left or right, or downflow • Two-stage gas valve and inducer operation • Variable-speed ECM blower operation
• 24V, 40 VA control transformer and blower relay • High-tech tubular aluminized steel primary heat exchanger • Airflow leakage less than 1% of total airflow • Insulated blower compartment • Internal condensate trap design • All models are propane convertible WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• Built-in, high-level self diagnostics with fault code displays standard on integrated control module • Electronic hot surface ignition
Min. Circuit Amps
Order #
Mfg. #
AFUE
BtuH Input
BtuH Output
Nom. CFM
Vent Size
Width
Height
Depth
Wt. Lbs.
L94-024 L94-025 L94-026 L94-027 L94-028 L94-029 L94-030
TM9V040A10MP12C 96.0% 40,000 TM9V060B12MP12C 96.0% 60,000 TM9V080B12MP12C 96.0% 80,000 TM9V080C16MP12C 96.0% 80,000 TM9V100C16MP12C 96.0% 100,000 TM9V100C20MP12C 96.0% 100,000 TM9V120D20MP12C 96.0% 120,000
38,000 58,000 77,000 77,000 96,000 96,000 115,000
1,000 1,200 1,200 1,600 1,600 2,000 2,000
9.0 9.0 9.0
3" 3" 3" 3" 3" 3" 3"
14-1/2" 17-1/2" 17-1/2"
33" 33" 33" 33" 33" 33" 33"
29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2"
113 122 126 136 142 145 156
12.0 12.0 14.0 14.0
21" 21" 21"
24-1/2"
97 to 98% AFUE Multi-Position Gas Furnaces CP9C Series, Modulating ECM
• Modulating gas valve, inducer and circulating blower • Modulating operation from 100% to 35% input in 100 increments with nearly constant temperature rise • Multi-position upflow, horizontal left or right or downflow • Airflow leakage rate of less than 1% of total airflow @ 1" ESP
• Stainless steel tube/aluminum fin secondary heat exchanger • Built-in, high-level, self-diagnostic controls with fault codes • External air filters (not included) • Insulated blower compartment • All models are propane convertible WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• ECM variable speed motor • Electronic hot surface ignition
• 24V, 40 VA control transformer and blower relay • Tubular aluminized steel primary heat exchanger
Min. Circuit Amps
Order #
Mfg. #
AFUE
BtuH Input
BtuH Output
Nom. CFM
Vent Size
Width
Height
Depth
Wt. Lbs.
L94-012 L94-013 L94-014 L94-015 L94-016 L94-017
CP9C060B12MP13C 97.5% 60,000 CP9C080B12MP13C 97.5% 80,000 CP9C080C16MP13C 97.7% 80,000 CP9C100C16MP13C 97.7% 100,000 CP9C100C20MP13C 97.7% 100,000 CP9C120D20MP13C 98.0% 120,000
58,000 77,000 78,000 97,000 97,000 116,000
1,200 1,200 1,600 1,600 2,000 2,000
7.0 7.5
3" 3" 3" 3" 3" 3"
17-1/2" 17-1/2"
33" 33" 33" 33" 33" 33"
29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2"
113 119 134 140 143 152
10.0 10.0 12.0 12.0
21" 21" 21"
24-1/2"
LP Conversion Kits WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Order #
Mfg. #
Description
For Use With
L38-276 L43-497 L44-611 L45-089 L49-520
S1-1NP0347 NG To LP Conv Kit S1-1NP0680 LP Conversion Kit S1-1NP0501 LP Conversion Kit S1-1NP0681 LP Conversion Kit S1-1NP0820 LP Conversion Kit
All Single or Two-Stage Gas Furnaces (80% AFUE & 90%+ AFUE) All Modulating Gas Furnaces: 80% AFUE & 90%+ AFUE (11 series) TG9S, GG9S (130K BtuH only),TG(8,L)S, GG(8,L)S (130K BtuH only) All Modulating Gas Furnaces: 80% AFUE (12C series), 90%+ AFUE (12 series)
Single or 2-Stage Gas Furnaces (80% AFUE & 90%+ AFUE)