©Johnstone Supply eCatalog 216

HVAC EQUIPMENT Coleman Gas Furnaces

80% AFUE Multi-Position Gas Furnaces TM8V & TMLV Series, Two-Stage, Variable-Speed, ECM, 33" Height • Communicating control • Multi-position upflow, horizontal left or right, or downflow • ECM variable-speed drive • Two-stage gas valve, inducer operation & variable-speed • Electronic hot surface ignition • Tubular aluminized steel primary heat exchanger • Built-in, high-level self diagnostics with fault code display • External air filters (not included)

• Airflow leakage less than 1% of nominal airflow for duct performance testing conditions • 24V, 40 VA control transformer and blower relay • Insulated blower compartment requirements; see www.JohnStonesupply.com for complete information and product selection WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov • All models are propane convertible • LoNOx models meet specific code

Min. Circuit Amps

Order #

Mfg. #

AFUE

BtuH Input

BtuH Output

Nom. CFM

Vent Size

Width

Height

Depth

Wt. Lbs.

Standard L94-031

TM8V060A12MP12C 80.0% 60,000 TM8V080B12MP12C 80.0% 80,000 TM8V080C16MP12C 80.0% 80,000 TM8V100C16MP12C 80.0% 100,000 TM8V100C20MP12C 80.0% 100,000 TM8V120C20MP12C 80.0% 120,000 TMLV060A12MP12C 80.0% 60,000 TMLV100C16MP12C 80.0% 100,000 TMLV120C20MP12C 80.0% 120,000

47,000 63,000 63,000 80,000 80,000 96,000 47,000 80,000 96,000

1,200 1,200 1,600 1,600 2,000 2,000 1,200 1,600 2,000

9.0 9.0

4" 4" 4" 4" 4" 4" 4" 4" 4"

14-1/2" 17-1/2"

33" 33" 33" 33" 33" 33" 33" 33" 33"

29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2"

94

L94-032 L94-033 L94-034 L94-035 L94-036 LoNOx L94-037 L94-040 L94-042

103 114 118 122 129

12.0 12.0 14.0 14.0

21" 21" 21" 21"

9.0

14-1/2"

94

12.0 14.0

21" 21"

118 129

80% AFUE Multi-Position Gas Furnaces CPLC Series, Modulating ECM • Modulating gas valve, inducer and circulating blower • ECM variable-speed motor • Multi-position upflow, horizontal left or right or downflow • Electronic hot surface ignition • 24V, 40VA control transformer and blower relay • Tubular aluminized steel primary heat exchanger

• Built-in, high-level self-diagnostic controls with fault codes • External air filters (not included) • Low sound levels • Insulated blower compartment • Airflow leakage rate of less than 1% of total airflow @ 1" ESP • All models are propane convertible • Meet specific LoNOx code requirements Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Min. Circuit Amps

Order #

Mfg. #

AFUE

BtuH Input

BtuH Output

Nom. CFM

Vent Size

Width

Height

Depth

Wt. Lbs.

L94-018 L94-019 L94-020 L94-021 L94-022

CPLC060A12MP13C 80.0% 60,000 CPLC080B12MP13C 80.0% 80,000 CPLC080C16MP13C 80.0% 80,000 CPLC100C16MP13C 80.0% 100,000 CPLC100C20MP13C 80.0% 100,000

47,000 62,000 62,000 78,000 78,000

1,200 1,200 1,600 1,600 2,000

7.0 7.5

4” 4” 4” 4” 4”

14-1/2" 17-1/2"

33” 33” 33” 33” 33”

29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2"

94

103 114 118 122

10.0 10.0 12.0

21" 21" 21"