©Johnstone Supply eCatalog 216
HVAC EQUIPMENT Evcon Gas Furnaces
95% AFUE Multi-Position Gas Furnaces RGF19*E Series, ECM Single-Stage,Standard • Multi-position upflow, horizontal left or right, or downflow • Blower-off delay for cooling SEER improvement • Built-in, high self level diagnostics with fault code
• 24V, 40VA control transformer and blower relay • Tubular aluminized steel primary heat exchanger • Secondary heat exchanger • Quiet inducer operation • External air filters (not included) • Propane convertible Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• Electronic hot surface ignition • 100% shut off main gas valve • 5-speed direct drive, ECM motor
CFM @ 0.5" ESP
Min. Circuit Amps
Order #
Mfg. #
AFUE
BtuH Input
BtuH Output Nom. CFM
Vent Size Width
Height
Depth
Wt. Lbs.
L60-187 L95-455 L95-456 L95-457 L95-458 L95-459 L95-460 L95-461 L95-462 L95-463
RGF19026AE08MP13 95.0% 26,000 25,000 800 RGF19040AE10MP13 95.0% 40,000 38,000 1,000
800
8.4
2" 2" 2" 2" 2" 2" 2" 2" 2" 2"
14-1/2" 14-1/2" 14-1/2" 17-1/2" 17-1/2"
33" 33" 33" 33" 33" 33" 33" 33" 33" 33"
29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2" 29-1/2"
113 113 118 122 126 136 139 142 145 156
1,035 1,124 1,243 1,304 1,607 2,001 1,602 2,006 2,005
10.0 10.0 10.0 10.0 12.0 15.8 12.0 15.8 15.8
RGF19060AE10MP13 95.0% 60,000 57,000 RGF19060BE12MP13 95.0% 60,000 57,000
1,000 1,200
RGF19080BE12MP13 95.0% 80,000 76,000 1,200 RGF19080CE16MP13 95.0% 80,000 76,000 1,600 RGF19080CE20MP13 95.0% 80,000 76,000 2,000 RGF19100CE16MP13 95.0% 100,000 95,000 1,600 RGF19100CE20MP13 95.0% 100,000 95,000 2,000 RGF19120DE20MP13 95.0% 120,000 114,000 2,000
21" 21" 21" 21"
24-1/2"
Heat Pumps LX Series, 14 SEER, Single-Phase, 1-1/2 To 5 Ton, R410A • Coated steel wire fan guard • High pressure relief valve and temperature sensor • High and low pressure switches • Factory installed filter-drier • Top discharge • Low operating sound levels • Adapter fitting required for 1-1/8" line sets • 208/230V Applications:
• Product not suitable for all regions Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Note: Installation must meet all Federal, State, and Local guidelines
BtuH Cooling
BtuH Heat ing Input
Min. Circuit Amps
Max. Fuse Size
Liquid Conn.
Suction Fitting
Order #
Mfg. #
Nom. Tons
HSPF
Width
Height
Depth
Wt. Lbs.
OEM TXV
14 SEER B78-398
RHP14L18B23S 1-1/2 RHP14L24B23S 2 RHP14L30B23S 2-1/2 RHP14L35B23S 3 RHP14L36B23S 3 RHP14L42B24S 3-1/2 RHP14L48B23S 4 RHP14L60B23S 5 REP14L24B21S 2 REP14L30B21S 2-1/2 REP14L36B21S 3 REP14L42B21S 3-1/2 REP14L48B21S 4 REP14L60B21S 5
18,000 18,000 9.0 24,000 24,000 9.5 30,000 30,000 9.5 35,000 35,000 8.9 36,000 36,000 9.0 42,000 42,000 8.5 48,000 48,000 9.0 60,000 60,000 9.0 18,600 16,000 8.55 25,000 22,200 9.0 29,000 28,000 9.0 35,000 34,000 8.55 41,000 39,000 8.2 46,500 45,500 9.0 56,500 56,000 9.0
12.0 15.4 18.1 20.5 22.0 26.8 30.8 31.7 10.2 14.1 16.4 19.6 23.5 24.5 29.1
20 25 30 35 35 45 50 50 15 20 25 30 45 45 50
3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”
3/4” 3/4” 3/4” 3/4” 3/4” 7/8” 7/8” 3/4” 3/4” 3/4” 3/4” 7/8” 7/8”
29-1/4" 29-1/4" 35-1/4" 35-1/4"
33-1/4” 36-1/4” 39-1/2” 39-1/2” 39-1/2” 39-1/2” 39-1/2” 42-1/2” 26-3/4” 33-1/4” 36-1/4” 36-1/4” 36-1/4” 39-1/2” 42-3/4”
29-1/4" 29-1/4" 31-3/4" 31-3/4" 34-1/4" 34-1/4" 34-1/4" 34-1/4"
120 131 176 176 230 230 235 256 122 131 165 191 210 224 249
B19-657 B19-657 B19-657 B19-657 B19-657 B19-659 B19-659 B20-463 B19-657 B19-657 B19-657 B19-657 B19-659 B19-659 B19-659
B78-399 B78-400 B78-401 B61-150 B61-298 B60-663 B60-664 B62-882 B62-883 B62-884 B62-885 B62-886 B62-887
38" 38" 38" 38"
1-1/8”*
14 SEER - ECM Matched B62-881 REP14L18B21S 1-1/2
24" 24"
24" 24"
29-1/4" 35-1/4" 35-1/4"
29-1/4" 31-3/4" 31-3/4" 34-1/4" 34-1/4"
38" 38"
1-1/8”*
Ask About Our Replenishment Programs Today!
773
JohnstoneSupply.com
Made with FlippingBook Annual report maker