96% AFUE Downflow/Horizontal Gas Furnaces GCVC96 Series, Two-Stage, Variable-Speed, ECM, Standard • Integrated communicating ComfortBridge™ Technology
• Auto-Comfort and enhanced dehumidification modes available • All models comply with California 40 ng/J Low NOx emissions standard • Fully insulated heat exchanger and blower section • Certified for direct vent (2-pipe)or non-direct vent (1-pipe) WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• Commissioning and diagnostics via on board Bluetooth with the CoolCloud phone and tablet application • Aluminized-steel tubular heat exchanger • Stainless-steel secondary heat exchanger
• Silicon Nitride ignitor • Two-stage gas valve • Two-speed induced draft blower • Self-diagnostic control board
CFM @ 0.5" ESP
Min. Circuit Amps
Order #
Mfg. #
AFUE
BtuH Input
BtuH Output Nom. CFM
Vent Size Width
Height
Depth
Wt. Lbs.
L94-207 L94-208 L94-209 L94-210 L94-211
GCVC960403BN 96.0% 40,000 GCVC960603BN 96.0% 60,000 GCVC960804CN 96.0% 80,000
38,400 57,600 76,800
1,200 1,200 1,600 1,600
1,376 1,091 1,681 2,069 2,110
7.8 7.8
2"-3" 2"-3" 2"-3" 2"-3" 2"-3"
17-1/2" 17-1/2"
34-1/2" 34-1/2" 34-1/2" 34-1/2" 34-1/2"
28-3/4" 28-3/4" 28-3/4" 28-3/4" 28-3/4"
116 119 143 145 158
10.6 14.4 14.4
21" 21"
GCVC961005CN 96.0% 100,000 96,000
GCVC961205DN 96.0% 120,000 115,200 2,000
24-1/2"
97% AFUE Upflow/Horizontal Gas Furnaces GMVM97 Series, Modulating, Variable-Speed, ECM, Standard • Integrated communicating ComfortBridge™ Technology
• Auto-Comfort and enhanced dehumidification mode • Certified for direct vent (2-pipe) or non-direct vent (1-pipe) • Left or right connection for gas and electrical service • Fully insulated heat exchanger & blower section WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• Commissioning and diagnostics via on board Bluetooth with the CoolCloud phone and tablet application • Aluminized-steel tubular heat exchanger • Stainless-steel secondary heat exchanger • Silicon Nitride igniter
• Self-calibrating modulating gas valve • Variable-speed induced draft blower • Self-diagnostic control board
CFM @ 0.5" ESP
Min. Circuit Amps
Order #
Mfg. #
AFUE
BtuH Input
BtuH Output Nom. CFM
Vent Size Width
Height
Depth
Wt. Lbs.
L95-533 L95-534 L95-535 L95-536 L95-537
GMVM970603BN 97.0% 60,000 GMVM970803BN 97.0% 80,000 GMVM970804CN 97.0% 80,000
58,800 77,600 78,400
1,200 1,200 1,600 2,000
1,386 1,536 1,668 2,153 2,231
8.8 8.8
2"-3" 2"-3" 2"-3" 2"-3" 2"-3"
17-1/2" 17-1/2"
34-1/2" 34-1/2" 34-1/2" 34-1/2" 34-1/2"
28-3/4" 28-3/4" 28-3/4" 28-3/4" 28-3/4"
118 121 142 144 157
11.6 15.4 15.4
21" 21"
GMVM971005CN 97.0% 100,000 97,000
GMVM971205DN 97.0% 120,000 116,400 2,000
24-1/2"
97% AFUE Downflow/Horizontal Gas Furnaces GCVM97 Series, Modulating, Variable-Speed, ECM, Standard • Integrated communicating ComfortBridge™ Technology
• Auto-Comfort and enhanced dehumidification mode • Certified for direct vent (2-pipe) or non-direct vent (1-pipe) • Left or right connection for gas and electrical service • Fully insulated heat exchanger & blower section WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• Commissioning and diagnostics via on board Bluetooth with the CoolCloud phone and tablet application • Aluminized-steel tubular heat exchanger • Stainless-steel secondary heat exchanger • Silicon Nitride igniter
• Self-calibrating modulating gas valve • Variable-speed induced draft blower • Self-diagnostic control board
Min. Circuit Amps
Order #
Mfg. #
AFUE
BtuH Input
BtuH Output
Nom. CFM
Vent Size
Width
Height
Depth
Wt. Lbs.
L95-538 L95-539 L95-540 L95-541
GCVM970603BN 97.0% 60,000 GCVM970803BN 97.0% 80,000 GCVM970804CN 97.0% 80,000 GCVM971005CN 97.0% 100,000
58,200 77,600 77,600 97,000
1,200 1,200 1,600 2,000
8.8 8.8
2"-3" 2"-3" 2"-3" 2"-3"
17-1/2" 17-1/2"
34-1/2" 34-1/2" 34-1/2" 34-1/2"
28-3/4" 28-3/4" 28-3/4" 28-3/4"
117 122 144 146
11.6 15.4
21" 21"
721