HVAC EQUIPMENT Goodman Gas Furnaces

80% AFUE Upflow/Horizontal Gas Furnaces GMES80 & GM9S80 Series, Single-Stage, Multi-Speed, ECM, Ultra LoNOx • Stainless-steel, dual-diameter tubular heat exchanger • Single-stage gas valve • Hot surface ignitor • Modulating draft inducer • Self-diagnostic control board • Multi-speed ECM blower motor • Foil faced insulated heat exchanger • California Ultra-LoNOx emissions compliant Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

CFM @ 0.5" ESP

Min. Circuit Amps

Order #

Mfg. #

AFUE

BtuH Input

BtuH Output Nom. Tons Nom. CFM

Vent Size Width

Height

Depth

Wt. Lbs.

L95-684 L60-635 L60-636 L60-637 L60-638 L60-639

GMES800403AU 80.0% 40,000 32,000 3 GM9S800403AU 80.0% 40,000 32,000 3 GM9S800603AU 80.0% 60,000 48,000 3 GM9S800604BU 80.0% 60,000 48,000 4 GM9S800804BU 80.0% 80,000 64,000 4 GM9S800805CU 80.0% 80,000 64,000 5

1,200 1,200 1,200 1,600 1,600 2,000

1,004 1,269 1,305 1,645 1,655 2,082

8.7 8.7 8.7

4" 4" 4" 4" 4" 4"

14" 14" 14"

33-3/8" 33-3/8" 33-3/8" 33-3/8" 33-3/8" 33-3/8"

28" 28" 28" 28" 28" 28"

86 86 90

12.45 12.45

17-1/2" 17-1/2"

100 108 116

12.7

21"

80% AFUE Upflow/Horizontal Gas Furnaces GMVS80-U Series, Single-Stage, Variable-Speed, Ultra LoNOx • Integrated communicating ComfortBridge™ technology

• Hot surface ignitor • Modulating draft inducer • Self-diagnostic control board • Left or right connection • Foil faced insulated heat exchanger WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

• Commissioning and diagnostics via on board Bluetooth with the CoolCloud™ phone and tablet application • Stainless-steel dual diameter tubular heat exchanger • Single-stage gas valve

Min. Circuit Amps

Order #

Mfg. #

AFUE

BtuH Input

BtuH Output Nom. Tons Nom. CFM

Vent Size Width

Height

Depth

Wt. Lbs.

L95-903 L95-904

GMVS800604BU 80.0% 60,000 GMVS800805CU 80.0% 80,000

48,000 64,000

1-1/2-4

1,600 2,000

11.6 11.6

4" 4"

17-1/2"

33-3/8" 33-3/8"

28" 28"

112 127

2-5

21"

80% AFUE Downflow/Horizontal Gas Furnaces GC9C80 Series, Two-Stage, Multi-Speed, LoNOX • Two-stage gas valve

• Two-speed induced draft blower • Fully insulated, heavy-gauge steel cabinet Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

• Multi-speed ECM circulator motor • SureStart ® Silicon Nitride igniter • Self-diagnostic control board • Low constant fan speed

CFM @ 0.5" ESP

Min. Circuit Amps

Order #

Mfg. #

AFUE

BtuH Input

BtuH Output Nom. Tons Nom. CFM

Vent Size Width

Height

Depth

Wt. Lbs.

L60-490 L60-491 L60-492 L60-493 L60-494 L60-495

GC9C800403AX 80.0% 40,000 32,000 3 GC9C800603AX 80.0% 60,000 48,000 3 GC9C800603BX 80.0% 60,000 48,000 3 GC9C800804BX 80.0% 80,000 64,000 4 GC9C800805CX 80.0% 80,000 64,000 5 GC9C801005CX 80.0% 100,000 80,000 5

1,200 1,200 1,200 1,600 2,000 2,000

1,335 1,289 1,322 1,491 2,074 1,720

8.7 8.7 8.7

4" 4" 4" 4" 4" 4"

14" 14"

33-3/8" 33-3/8" 33-3/8" 33-3/8" 33-3/8" 33-3/8"

28" 28" 28" 28" 28" 28"

105 107 107 121 129 131

17-1/2" 17-1/2"

12.45 15.32 15.32

21" 21"

716

©2023 Johnstone Supply, LLC

Made with FlippingBook Annual report maker