©Johnstone Supply eCatalog 216
HVAC EQUIPMENT First Co Air Handlers
Ceiling Fan Coils CDXQ Series, Uncased, Horizontal Recessed, 1-1/2 To 3 Ton • Copper tube Heating/Cooling Coils • Two speed fan operation
®
by First Co.
• Piston type metering device • 120V relay • 24V transformer • TXV Models come with factory installed Thermostatic Expansion Valves Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• Factory installed circulating pump • Sloped and insulated drain pan • Electrical service switch • Factory installed freeze protector • Manual air bleed port
Conn. Size HW Drain Conn. Width
Order #
Mfg. #
Nom. Tons Nom. CFM Rows
Volts
Conn. Size
Height
Depth
Wt. Lbs.
Piston Models L93-415 18CDXQ
1-1/2 1-1/2
720 710 860 880
3 3 4 4 4 4 4 3 3 4 4 4 4
120 120 120 120 120 120 120 120 120 120 120 120 120
5/8" 5/8" 5/8" 5/8" 7/8" 7/8" 7/8" 5/8" 5/8" 5/8" 7/8" 7/8" 7/8"
5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8"
3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"
45-1/8" 45-1/8" 51-1/8" 51-1/8" 57-1/8" 57-1/8" 64-1/8" 45-1/8" 51-1/8" 51-1/8" 57-1/8" 57-1/8" 64-1/8"
10" 10" 10" 10" 10" 10" 10" 10" 10" 10" 10" 10" 10"
21" 21" 21" 21" 21" 21" 21" 21" 21" 21" 21" 21" 21"
74 74 82 82
L93-416 L93-417 L93-418 L93-419 L93-420 L93-421 L94-157 L94-158 L94-159 L94-160 L94-161
19CDXQ 24CDXQ 25CDXQ 30CDXQ 31CDXQ 37CDXQ
2 2
2-1/2 2-1/2
1,050 1,100 1,310
103 103 103
3
TXV Models L94-156
18CDXQ-R410-TXV-FR 1-1/2 24CDXQ-R410-TXV-FR 2 25CDXQ-R410-TXV-FR 2 30CDXQ-R410-TXV-FR 2-1/2 31CDXQ-R410-TXV-FR 2-1/2 37CDXQ-R410-TXV-FR 3
720 860 880
74 82 82
1,050 1,100 1,310
103 103 103
Ceiling Fan Coils HBC Series, Uncased, Horizontal Concealed, 3/4 To 3 Ton • Copper tube/aluminum coils • Standard PSC motor • Sloped and insulated drain pan • 24V transformer
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Order #
Mfg. #
Nom. Tons Nom. CFM Rows
Volts
Conn. Size Conn. Size CW Conn. Size HW Drain Conn. Width
Height
Depth Wt. Lbs.
Left Hand Models L93-396
3HBC3-LH 3/4 4HBC3-LH 1 6HBC3-LH 1-1/2
300 400 600 800
3 3 3 3 3 3 3 3 3 3 3 3
120 120 120 120 120 120 120 120 120 120 120 120
5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8"
5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8"
5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8"
3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4"
30-1/8" 36-1/8" 40-1/8" 46-1/8" 52-1/8" 59-1/8" 30-1/8" 36-1/8" 40-1/8" 46-1/8" 52-1/8" 59-1/8"
10" 10" 10" 10" 10" 10" 10" 10" 10" 10" 10" 10"
21-1/2" 39 21-1/2" 48 21-1/2" 54 21-1/2" 57 21-1/2" 67 21-1/2" 87 21-1/2" 39 21-1/2" 48 21-1/2" 54 21-1/2" 57 21-1/2" 66 21-1/2" 87
L93-398 L93-400 L93-402 L93-404 L93-406 L93-399 L93-401 L93-403 L93-405 L93-407
8HBC3-LH 2
10HBC3-LH 2-1/2
1,000 1,300
13HBC3-LH 3
Right Hand Models L93-397
3HBC3-RH 3/4 4HBC3-RH 1 6HBC3-RH 1-1/2
300 400 600 800
8HBC3-RH 2
10HBC3-RH 2-1/2
1,000 1,300
13HBC3-RH 3
Single-Piece Air Handlers HBQB Series, Upflow/Horizontal Cooling or Heat Pump/Hot Water Heating, 1-1/2 To 5 Ton • Copper tube/aluminum fin heating and cooling coils • Primary and secondary drains • 4-way airflow (kit required for counterflow - 60HBQB not approved for counterflow installation • 120/24V relay/transformer Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov • Factory installed filter • Automatic pump timer
®
by First Co.
• Blower-on delay • Blower-off delay
CFM @ 0.5" ESP
CFM High @ 0.3 ESP
Min. Circuit Amps
Max. Fuse Size
Suction Fitting
Order #
Mfg. #
Nom. Tons Nom. CFM
Liquid Conn.
Width
Height
Depth
Wt. Lbs.
L93-428 L93-429 L93-430 L93-431 L93-432 L93-433
18HBQB 1-1/2
810 950
810 950
650 790 995
5 7 7
15 15 15 15 15 20
3/8" 3/8" 3/8" 3/8" 1/2" 1/2"
5/8" 5/8" 3/4" 3/4" 7/8" 7/8"
20" 20" 20" 20"
40" 40" 42" 42" 48" 52"
18-1/2"
130 130 145 147 212 270
24HBQB 2
20" 23" 23"
30HBQB 2-1/2
1,120 1,340 1,810 2,160
1,120 1,340 1,810 2,160
36HBQB 3 48HBQB 4 60HBQB 5
1,190 1,660 1,980
12 14 16
21-1/4" 25-1/4"
26-1/4" 26-1/2"
655
JohnstoneSupply.com
Made with FlippingBook Annual report maker