©Johnstone Supply eCatalog 216
HVAC EQUIPMENT Water Heater Parts
Water Heater Thermostats Replaces APCOM Thermostats • Replacements for domestic water heaters, for State water heaters and most new production water heaters
• Can replace old style Robertshaw, APCOM and Therm-O-Disc ® • Temperature range: 120°F to 160°F • Electrical rating: 7200 watts @ 240V
Each
Fig. Order #
Mfg. #
Type
A
B
N45-065 5600-411 N45-066 5600-311
A B
Single Throw
59.00 89.00
Single Pole/Double Throw w/ Reset
Electric Water Heater Thermostats • 59T series adjustable controls and 66T series manual reset limits • Found on A.O. Smith, Rheem and American Water Heater Group • New “US Standards” thermostats with 90°F to 150°F range
• Pointer set at 120°F to satisfy industry's scalding concerns in residential use WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
A
B
C
D
E
F
Each
Fig. Order #
Mfg. #
Calibration Volts Application
Temp. Range Type
N45-073 N45-074 N45-075 N45-076
A B C D E
756-50 120°F 240 Upper Combination T-Stat for 2 Element Tanks
90°F to 150°F Auto Reset SPDT 90°F to 150°F SPST T-Stat Only
85.00 39.99 38.49 55.00
755-1 754-1 756-1
120°F 240 Lower T-Stat for 2 Element Tanks
170°F 240 High-Limit Manual Reset for 2 Element Tanks 120°F 240 Upper Combo Cycling T-Stat Only for 2 Element Tanks
170°F
DPST
90°F to 150°F SPDT
N45-077 755-50 120°F 240 Combination 240VAC T-Stat w/ Reset for Single Element Tanks 90°F to 150°F SPST T-Stat w/ DPST Manual Reset 85.00 F N45-078 755-100 120°F 120 Combination 120VAC T-Stat w/ Reset for Single Element Tanks 90°F to 150°F SPST T-Stat w/ SPST Manual Reset 79.00
Gas Water Heater Controls • 110 TS water heater thermostat with automatic energy cutoff device (ECO); gas shuts off at excessive water temperature of 160°F
• Universal size 1/2” pipe inlet; 1/2” inverted flare outlet • 1-3/8” shank length; 5-1/2” sensing element • Includes 3/8” NPT reducer bushing
Each
Order # Mfg. #
Description
Pressure Setting
Pilot
N45-182
110-202 Is Not Pilot Adjustable
4.0” W.C. 3.5” W.C.
Fixed
445.00 379.00
N45-014 110-326 Includes Pilot Adjustment Key
Adjustable
Gas Water Heater Control • Automatic shutoff on main and pilot gas in the event of pilot failure • Built-in E.C.O. (energy cut off) non-cycling high limit
• 1/2" inlet; 1/2" inverted flare outlet with adapter fittings for 3/8" FPT; 3/4" x 1-1/4" shank; 4-1/2" insertion bulb WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Each
Order #
Mfg. #
Pressure Setting
Pilot
N45-205
37C73U-168
3.5" W.C.
Fixed
295.00
583