©Johnstone Supply eCatalog 216

DEFINITE PURPOSE MOTORS 3-3/8" OEM Replacement Draft Inducers

Bearing Type

Safety Switch Replaces

Outlet Flange

Wt. Lbs.

Each

Fig. Order # Mfg. # Motor Type HP

Volts

RPM 3000

Speeds F/L Amps Rot.

CFM

X89-594

L

66787 —

1/30 1/29 1/25 1/25 1/24 1/20 1/18 1/16

120

1

1.2

CCWLE Ball CCWSE Slv CW Slv CW Ball CW Ball CWSE Slv CW Ball CW Ball

No D330787P01

— — 6.85

359.00 565.00 455.00 595.00 1545.00 975.00

X89-695 A150 —

M N

208–230 3000

— 0.50 — 1.35

No 7021-7833, 7021-8928 — — 3.60

X82-106

A196 —

115

3200

No 7021-11544S, 7021 11544, 7021-9065

— — 5.60

— X82-172 — X82-150

A360 — A274 — A271 — A195 — A270 — A191 — A272 — A273 — A197 —

115

2700

— 1

No 7002-2532 No 7062-3973 No 7062-3956 No 7062-3969

— — 5.80 — — 4.20 — — 5.00

208-230 3500

— 0.28 — 0.70 — 0.62 — 1.80

X89-564 A130 —

O

115

3450

— X82-147

208-230 3500

— — 10.30 1645.00

X89-983

P

115

3400

No D330757P03, D342094P03, X38040313070

— — 6.20

489.00

X82-146 X82-104

Q R

1/15 1/15 1/12

208-230 3350/2800 — .42-.50 CCW Ball

No 7062-5033 No 7021-6683 No 7062-3971 No 7062-3972

— — 6.90 — — 6.40 — — 6.00 — — 6.00 — — 5.80

1045.00 739.00 1645.00 1645.00 625.00

208-230 3000 208-230 3500 208-230 3500

— 0.8 — 0.65 — 0.62

CCW Slv CW Ball CW Ball CW Ball

— X82-148 — X82-149

1/8

X82-107

S

VAR 33-110 1500-4700 — 1

No 7092-0238S, 7092 0238

X83-725

83/43 — 5.85

269.00

T

66311 PSC

— 208-230 2800/1500 2

0.21/0.16 CCWSE Ball

No BLW01311,

D965130P01, Y3S 248B51A, 10563

X83-760 X83-759

T U

A070 Shaded Pole — 115

3400 3300

1 2

2.35

— Ball

— 70-104157-02 — D345183P01; BLW01401

— No — No

10.00

595.00

— 120

0.60/0.36 — Ball

10.00 1045.00

A277 Permanent Split Capac itor

Williamson Draft Inducer Blowers Direct Replacement for Williamson • S88-841 replaces Williamson #02-568, #7021-5510 • X89-520 replaces Williamson 100,000 Btu furnaces, #7021-6999, #7021-7042

Note: X89-520 leads may require some modification on certain replacements.

Bearing Type

Safety Switch Wt. Lbs.

Each

Fig. Order # Mfg. # HP

Volts

RPM F/L Amps Rot.

S88-841 A080 1/45 115 X89-520 A118 1/15 115

A B

3000 1.10 CWSE Slv 3000 1.80 CWSE Slv

No No

5.25 6.50

619.00 745.00

A

B

• Up-to-date models and compatibility The Mini-Split Selector Provides You With: Current and accurate AHRI certified system matches System specific critical installation supplies Incorporates SEER2 Ratings to support 2023 Energy Eiciency Regulations • • •

Quick • Accurate • Easy Mini-Split S lector Mini-Split Selector

CHECK YOUR INVENTORY TO MAKE SURE IT IS SEER COMPLIANT.

58

©2023 Johnstone Supply, LLC

Made with FlippingBook Annual report maker