HYDRONICS Boiler Controls
Low Water Cut-Off For Water Boilers • For hot water boilers of any size, including steam • Protects against low water conditions with circuit for low water alarm • Manual reset • Designed with 1" NPT equalizing pipes • Maximum boiler pressure: 50 PSI
• 120VAC — maximum F/L amps 10.2; maximum L/R amps 61.2; 240VAC — maximum F/L amps 5.1; maximum L/R amps 30.6 • Pilot duty: 120/240VAC, 60 Hz, 125VA; 115VDC, 0.5A WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Order #
Mfg. #
Model #
L86-135
143100
63-M
No. 2 Switches • For series 47, 247, 51, 51S, 53, 63 and 847 water feeders to add low water cut-off function • Provides flexibility for selection of functions desired
• L38-775 has manual reset WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Order #
Mfg. #
Model #
Description
Volts
L38-774 L38-775
110000 110100
2
Low Water Cut-Off Switch 120/240 Low Water Cut-Off Switch 120/240
2M
Low Water Cut-Off For Hot Water Boilers Electric • For residential and, where codes allow, commercial applications • Electro-mechanical operation • Automatic reset • No blow-down required Specifications:
• Maximum water pressure: 160 PSI • Voltage across probe to ground: 125VAC • Power consumption: 15VA • Probe sensitivity: 6,000 ohms WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• Maximum ambient temperature: 120°F • Maximum water temperature: 250°F
Fig. Order #
Mfg. #
Model # RB-122
Volts
For Use With
A
B
L38-788
A
144676
120VAC
—
Replacement Probe B L41-531 354083
PA-RB-122
—
RB-122
Low Water Cut-Off for Hot Water Boilers Electric • For residential applications • Automatic reset resumes operation after a power outage
• LED for power to the unit and presence of water in the boiler WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Order #
Mfg. #
Model # RB-24E
Volts
L38-787
144692
24
Universal Wire Harness Kits For Atmospheric and Sealed Combustion Boilers • Used with all RB-24s (sold separately)
• Both harness kits consist of three Molex wiring harnesses; a common “connector cable” and two “Y” harnesses WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• L41-528 used in most 24-volt “atmospheric” hot water boiler applications that use 6-pin aquastats or vent damper • L41-529 used in 24-volt “sealed combustion” hot water boiler applications
Fig. Order #
Mfg. # Model #
Volts
Fig. Order #
Mfg. # Model #
Volts
A
B
L41-528
L41-529
A
144681 UWH-RB-24-A 24
B
144682 UWH-RB-24-S 24