©Johnstone Supply eCatalog 216
OIL HEAT Fuel Units
Delay Valve Kit • Cuts oil flow instantly at burner shutdown for cleaner cut-offs and reduced sooting • Includes Precision Delay timer to ensure that airflow is established prior to oil flow
• Includes valve and all hardware required for installation WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Each
Order #
Mfg. #
Description
L40-791
2182602U
Delay Valve Kit
215.00
Fuel Oil Units Model A Single-Stage, Model B Two-Stage • Contamination resistant control valve • No leak easy flow bleed valve • High contact ratio precision matched gears for long life • Double-lip shaft seal • Original diaphragm/cone valve • Involute tooth-form gears for quiet operation • Two-stage units for high lift application • Factory set at 100 PSI • Pressure adjustable from 100 to 200 PSI @ 3450 RPM, 100 to 200 PSI @ 1725 RPM • Lift or gravity feed applications with 10 PSI maximum inlet/return pressure
• Suitable for No. 1 and No. 2 fuel oil or kerosene • May be mounted in any position, except upside down • L86-145 through L86-148 are for installations requiring up to 6" HG vacuum single pipe and 12" HG vacuum two pipe • L86-149 and L86-150 are rated to 17" HG vacuum two pipe Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Strainer & Nozzle Rating @ 100 PSI
Each
Order #
Mfg. #
RPM
Rot. RH LH RH LH RH RH
Nozzle Port Location
Stages Single Single Single Single
L86-145 L86-146 L86-147 L86-148 L86-149 L86-150
A1YA-7912B 1725 A1YC-7914B 1725 A2VA-7116B 3450 A2VD-7119B 3450 B1VA-8212B 1725 B2YA-8916B 3450
RH LH RH RH RH RH
7 GPH 7 GPH 3 GPH 3 GPH 3 GPH 3 GPH
325.00 345.00 275.00 429.00 615.00 469.00
Two Two
Shutoff Valves • Top quality field-proven valves provide instantaneous fuel supply cutoff back-up in oil fuel circuits • Wired in parallel with burner motor, valve
• Used with fuel units rated up to 16 GPH • Suitable for use with No. 1 and No. 2 fuel oil or kerosene • Non-delay opening response, valves mount in any position
closes whenever current to motor is interrupted, blocking oil flow to nozzle
Each
Fig. Order #
Mfg. #
Mounting
Volts
Max. Pressure
L37-520 L37-521
A B
R642NL C642NR
Pump Burner
115VAC 115VAC
300 300
145.00 135.00
A
B
Oil Burner Primary Controls • Automatic, non-recycling control of an intermittent ignition oil burner system • External button to manually reset safety switch after safety shutdown • Mounts on standard 4" x 4" junction box • Requires C554A Cadmium Sulfide Flame Detector ( L37-030 ) and 24VAC thermostat
• Electrical rating (full load): 7.4A @ 120VAC, 3.7A @ 240V; 360VA ignition rating for burner motors • Ambient temperature range: -40°F to +130°F • L37-026 includes 40 VA transformer and Y and G terminals for connection of cooling equipment
A
B
Each
Each
Fig. Order # Mfg. #
Safety Timing
Fig. Order # Mfg. #
Safety Timing
L37-519
L40-026 R8184G4082 45 Seconds
A A
R8184G4009 45 Seconds
299.00 425.00
A B
495.00 535.00
L39-034 R8184G4066 15 Seconds
L37-026
R8184M1051 45 Seconds
453
JohnstoneSupply.com
Made with FlippingBook Annual report maker