©Johnstone Supply eCatalog 216

COMMERCIAL CONTROLS Pneumatics

Humidity Transmitters With Temperature Sensor • Provide both humidity and temperature sensing in room wall-mount applications • The transmitter offers local warmer/cooler temperature setpoint adjustment and temporary occupancy override • The humidity sensor provides Relative

occupancy features that match the application and transmitter • Power requirements: 4.5 to 7.5 mA at 14 to 30VDC and 5K ohm Load, or 18 to 25 mA at 20 to 30VAC and 5K ohm Load • Sensor type: 1,000 ohm Thin Film Nickel • Coefficient: approximately 3 ohm per F° (5.4 ohm per C°) • Reference Resistance: 1,000 ohm at 70°F (0°C) • Accuracy: ±0.34F° at 70°F (±0.18C° at 21°C) • Platinum sensing element WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Humidity (RH) accuracy of ±2% or ±3% RH and measures RH over the entire range of 0 to 100% • Include screw terminal block terminations that provide flexibility for field wiring • Controller configuration DIP Switch allows users to adjust the room comfort and choose

Each

Order #

Mfg. #

Description

L46-866 L46-867 L46-868 L46-869

HE-68P2-0N00WS No Warmer /Cooler Temperature Setpoint Adjustment Override HE-68P2-1N00WS Warmer /Cooler Temperature Setpoint Adjustment Override HE-68P3-0N00WS No Warmer /Cooler Temperature Setpoint Adjustment Override HE-68P3-1N00WS Warmer /Cooler Temperature Setpoint Adjustment Override

879.00 905.00 815.00 895.00

TE-6800 Series Temperature Sensors • Provides temperature sensing in room wall mount applications • Platinum sensing element • Allows local setpoint temperature adjustment and temporary occupancy override

Specifications: • Temperature sensor: 1000 ohm thin-film platinum • Temperature Coefficient: Approximately 2 ohms per F° (3.9 ohms per C°) • Reference Resistance: 1000 ohms at 32°F (0°C) • Accuracy: ±0.35F° at 70°F (±0.19C° at 21°C) • Field Connections: 1. Modular Jack- 8-position modular jack connector. 2. Terminal Block- screw type terminals for 18 to 24 AWG wire WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

• An occupancy override button allows the user to request a time-of-day scheduling override when the space is occupied outside of the normal occupied hours schedule • All sensors have DIP switches that enable or disable unit functions • All models include a Zone Bus access port for connecting accessories to access the 6-pin modular jack

Each

Order #

Mfg. #

Description

L46-870 L46-871 L46-872 L46-873 L46-874

TE-68PP-0N00S Modular Jack Connection TE-68PP-1N00S Modular Jack Connection TE-68PT-0N00S Terminal Block Connection TE-68PT-1N00S Terminal Block Connection

235.00 185.00 265.00 175.00

NS-WALLPLATE-0 Adapts a TE-6800 Sensor (80 x 80 mm) to a standard 80 x 120 mm wallbox

36.49

CO2 Transmitters • For measuring and transmitting CO2 levels, ranging from 0 to 2,000 parts per million (ppm), within Heating, Ventilating, and Air Conditioning (HVAC) CO2 applications • Specific HVAC CO2 applications include Demand Control Ventilation (DCV), fresh air

and Indoor Air Quality (IAQ), and rooftop air handling Economizer controls systems • Designed to work as in stand- alone mode or as part of any integrated Building Automation System (BAS) WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Each

Order #

Mfg. #

Description

L46-875 L46-877 L46-878

CD-W00-00-2 Wall Mount CO2 Transmitter with Logo ACC-DWCLIP-0 Drywall Spring-Clip Mounting Kit

785.00

13.99

Y65T31-0

Multiple Primary Transformer, 40 VA, 120/208/240 V Primary, 24 V Class 2 Secondary with Screw Terminals: Foot Mounting or 4 x 4 in. (100 x 100 mm) Plate

165.00

406