©Johnstone Supply eCatalog 216

HVAC CONTROLS Pilot Burner Accessories

Pilot Burner Tubing • Tubing is 1/4" x 60" • Includes four cc. fittings

Each

Order # Mfg. #

Description

L39-520 Y99AR-1

1/4" x 60" Aluminum Pilot Gas Tube

65.00

Dead Soft Aluminum Tubing

Each

Order # Length

O.D. 1/8" 1/4" 1/4" 3/8" 3/16"

B92-025

50'

115.00 109.00 129.00 155.00 35.99

B92-026 50'

B11-763

5'

B92-027 50' B92-028 50'

OEM Replacement Mercury Flame Sensors • Mercury flame sensors consist of mercury filled sensing bulb, capillary and diaphragm assembly mounted on a switch mechanism • Pilot flame heat vaporizes mercury within sensing bulb, which actuates the snap-action switch

• Sensors furnished with either spade terminals (3049 series) for point to point wiring or direct plug-in connections (3098 series), eliminating point-to-point wiring • L37-170 includes adapter fittings WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

• Switch may be SPST or SPDT and is usually wired in series with main valve relay in most automatic ignition systems

Each

Order #

Mfg. #

Capillary Length Description

L37-169 L36-974 L37-170

3049-115 3098-134 3098-156

48" 48" 48"

2 — 1/4" Spade Terminals, One Pin Terminal

759.00 759.00 675.00

Flame Sensor - Plug-in Connector

Plug-in Connector

Mercury Flame Sensor • Designed for use with White-Rodgers diaphragm, “Cushioned Power” or “Silent Knight” valves having plug-in receptacle • Sensor combines snap-action SPDT switch and mercury actuated thermal element • Use with natural, manufactured or mixed gases and with LP gases where means are provided for obtaining automatic pilot gas shutoff • Sensors are recycling type, which require relighting or possible restoration of proper gas pressure to return to operation

• SPDT switch can energize ignitor circuit to relight pilot (as with rooftop units) Specifications: • Timing: Contacts close approximately 60 seconds after pilot ignition; open approximately 40 seconds after flame is extinguished • VA rating 120V and 240V is 125; VA rating 30V is 90 WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Each

Order #

Mfg. #

Capillary Length

L36-134

30A46-5

48"

815.00

Mercury Flame Sensor • Prevents gas flow to main burner if pilot flame is not burning or is insufficient to properly ignite main burner • Contains rugged snap-action switch and powerful mercury actuated thermal element • Use with natural, manufactured or mixed gases and with LP gases where means are

provided for obtaining automatic pilot gas shutoff • Sensors are recycling type which require relighting or possible restoration of proper gas pressure to return to operation WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Each

Order #

Mfg. #

Capillary Length

Type

L39-553

3046-5

48"

Screw

815.00

383

JohnstoneSupply.com

Made with FlippingBook Annual report maker