©Johnstone Supply eCatalog 216

HVAC CONTROLS Gas Ignition Controls

Universal Intermittent Pilot Ignition Controls • L38-259 is universal replacement for intermittent pilot controls • L38-259 is 24VAC, 50/60 Hz pilot 1A max. and main 2A max. • L38-259 100% shutoff/lockout with 5 minute continuous retry

installed, or has been replaced with a Lennox 65K93 ignition replacement kit • L38-956 is 24VAC, 50/60 Hz pilot 1A max. and main 2A max • Ignition trial time: 25 seconds for L38-259 ; 85 seconds for L38-956 • Prepurge time: 0 (zero) seconds for L38-259 ; 15 seconds for L38-956 WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

• L38-956 is replacement for Lennox G20, G20R, G23 and G26 series unit that has a Johnson Controls G776RGD-1, G776RGD-2, G776RGD-10 or G776RGD-11 ignition control

Each

Order #

Mfg. #

L38-259 L38-956

C610U-1CJ

315.00 329.00

C661PGA-1CJ

Direct Spark Ignition Controls • OEM Replacement Ignition Controls • Offered as direct replacement for Johnson Controls OEM models, with same mounting holes for quick change-out Specifications: • Electrical rating: 24VAC, 50/60 Hz

• Flame sensing current: 0.15 µA minimum • Flame failure response time: 2 seconds maximum WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Each

Order #

Mfg. #

Ignition Trial Time

Ignition Trials

Prepurge Period

Description

L40-352 L40-353

C161FJD-1CJ 4 Seconds C161KKD-1CJ 8 Seconds

3 3

Direct Spark Ignition Control Direct Spark Ignition Control

299.00 299.00

30 Seconds

Direct Spark Ignition Module • Replacement model for G891TCA-8103 Lennox Pulse furnace • Replaces Lennox parts #60J00, 52J18, 97H02, 96C66, 86H30, 77C38, 77C3801, 73K86, 73K8601, 56G14, 41F46, 99C97, and 99C9701PR • Also replaces Johnson Controls # G891TCA-810

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Note: The unit comes complete with the 6 pin connector, ground wire, 2 terminals to convert the spark pin to a ¼” terminal and the sensor 3/16” terminal to the ¼”, and resistor for the fan timer.

Each

Order #

Mfg. #

Ignition Trial Time

Prepurge Period

Description

L46-308

BGN891-1CJ 8 Seconds

30 Seconds

Direct Spark Ignition Control

429.00

Gas Transformers • 120 Volts • 50/60 Hz • One end ground

• Designed with high temperature wire • L81-194 is a replacement for Gordon Piatt transformers

Each

Order # Mfg. #

VA Rating

Primary Voltage

Secondary Voltage

L81-194 L81-195

1092-S 1092-F

120V 120V

180 180

6000 6000

295.00 295.00

Thermocouples • Universal adapter and push-in clip for one hand installation • Thickest inner copel element for longest life

• Bottom-lock design for easy installation from bottom

Each

Order # Mfg. #

Length

L37-020 L36-911 L37-021

Q340A1066 Q340A1074 Q340A1082

18” 24” 30” 36” 48”

28.99 29.99 31.49 32.99 36.49

L36-912 Q340A1090

L37-022

Q340A1108

375

JohnstoneSupply.com