HVAC CONTROLS Gas Pilot Ignition Systems

OEM Replacement Pilot Relite Control • Will spark until flame is sensed between electrode and ground • Relite control detects flame through flame conduction

• If flame is extinguished during call for heat, relite control will begin sparking the instant the flame goes out Specifications: • 0.03A, 24VAC — 1/4" male spade terminals • High voltage connection — 1/4" male spade WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

• When flame current is sensed between electrode and pilot burner ground, relite control stops sparking

Each

Order #

Mfg. #

Description

L36-975

5059-134

Spark Ignitor

379.00

Ignition Electrode Assembly • Replaces cycle-pilot ignition electrode and cable assemblies • 24" lead with slip on bracket and perforated mounting strap

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Each

Order #

Mfg. #

Description

L36-976

760-56

Electrode Assembly

219.00

Universal Hot Surface Ignition Control • Microprocessor-based gas ignition control • Tri-color LED indicator for diagnostics • Direct and indirect flame sense

coded timing label, program keys and pre printed hanging carton Specifications: • Relay load settings: Valve relay: 1.5A @ 28VAC 50/60 Hz .6pf • Ignitor relay: 1.52 115VAC 50/60 Hz resistive • Electrical rating: Input 18 to 30VAC, 25VAC Nominal Max. Input Current @ 25VAC; .250mA @ 25°C • Dimensions: 4.13" W x 4.13" H x 1.5" D WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

• Prepurge feature allows the operation of an induced draft blower to purge the combustion chamber during period between initial thermostat contact closure and the start of the ignition cycle • Retry feature allows controls to re-initiate ignition sequence in the event that the flame is undetected, or established and then lost • Kit includes mounting hardware, double-sided foam back tape, cross-reference guide, color

Each

Order #

Mfg. #

Description

L39-565

50E47-843

Carbide Non-Integrated HSI Furnace Control

305.00

Program Key Specifications Quick Reference

Ignition Trial Time

Ignition Trial Time

Key

Retries

Prepurge 30 Sec. 30 Sec. 30 Sec.

Warm-up 45 Sec. 45 Sec. 45 Sec.

Key

Retries

Prepurge 30 Sec. 30 Sec. 30 Sec.

Warm-up 45 Sec. 17 Sec. 17 Sec.

A-Blue B-Red

4 Sec. 4 Sec. 7 Sec

0 2 0

D-Violet

7 Sec. 4 Sec. 7 Sec.

2 2 2

E-Orange F-Yellow

C-Green

Flame Sensor • High quality Alumina ceramic insulator • High temperature Kanthal flame rod material that can withstand 1800°F • Teflon insulated (250°C rating) lead wire

• Single screw, plated steel mounting bracket WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Each

Order #

Mfg. #

Description

L45-321

760-401

30” Lead Length

45.49

Silicon Carbide Integrated Furnace Control • Controls gas valve, ignitor, two speed blower motor, inducer, humidifier (both 120V & 24V input) and air cleaner • Includes flash code diagnostics • Twinning

• Fused to protect low voltage system transformers • Adjustable blower relay WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Each

Order #

Mfg. #

OEM Replacement for

L45-392

50T35-743 Goodman: B1809906, B1809908, B1809910, B1809913, B1809913S; UTEC: 1012-933D; Texas Instruments: 41F-5; White-Rodgers: 50T35-730

319.00

358

©2023 Johnstone Supply, LLC

Made with FlippingBook Annual report maker