©Johnstone Supply eCatalog 216
HVAC CONTROLS Gas Pilot Ignition Systems
OEM Replacement Pilot Relite Control • Will spark until flame is sensed between electrode and ground • Relite control detects flame through flame conduction
• If flame is extinguished during call for heat, relite control will begin sparking the instant the flame goes out Specifications: • 0.03A, 24VAC — 1/4" male spade terminals • High voltage connection — 1/4" male spade WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• When flame current is sensed between electrode and pilot burner ground, relite control stops sparking
Each
Order #
Mfg. #
Description
L36-975
5059-134
Spark Ignitor
379.00
Ignition Electrode Assembly • Replaces cycle-pilot ignition electrode and cable assemblies • 24" lead with slip on bracket and perforated mounting strap
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Each
Order #
Mfg. #
Description
L36-976
760-56
Electrode Assembly
219.00
Universal Hot Surface Ignition Control • Microprocessor-based gas ignition control • Tri-color LED indicator for diagnostics • Direct and indirect flame sense
coded timing label, program keys and pre printed hanging carton Specifications: • Relay load settings: Valve relay: 1.5A @ 28VAC 50/60 Hz .6pf • Ignitor relay: 1.52 115VAC 50/60 Hz resistive • Electrical rating: Input 18 to 30VAC, 25VAC Nominal Max. Input Current @ 25VAC; .250mA @ 25°C • Dimensions: 4.13" W x 4.13" H x 1.5" D WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
• Prepurge feature allows the operation of an induced draft blower to purge the combustion chamber during period between initial thermostat contact closure and the start of the ignition cycle • Retry feature allows controls to re-initiate ignition sequence in the event that the flame is undetected, or established and then lost • Kit includes mounting hardware, double-sided foam back tape, cross-reference guide, color
Each
Order #
Mfg. #
Description
L39-565
50E47-843
Carbide Non-Integrated HSI Furnace Control
305.00
Program Key Specifications Quick Reference
Ignition Trial Time
Ignition Trial Time
Key
Retries
Prepurge 30 Sec. 30 Sec. 30 Sec.
Warm-up 45 Sec. 45 Sec. 45 Sec.
Key
Retries
Prepurge 30 Sec. 30 Sec. 30 Sec.
Warm-up 45 Sec. 17 Sec. 17 Sec.
A-Blue B-Red
4 Sec. 4 Sec. 7 Sec
0 2 0
D-Violet
7 Sec. 4 Sec. 7 Sec.
2 2 2
E-Orange F-Yellow
C-Green
Flame Sensor • High quality Alumina ceramic insulator • High temperature Kanthal flame rod material that can withstand 1800°F • Teflon insulated (250°C rating) lead wire
• Single screw, plated steel mounting bracket WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Each
Order #
Mfg. #
Description
L45-321
760-401
30” Lead Length
45.49
Silicon Carbide Integrated Furnace Control • Controls gas valve, ignitor, two speed blower motor, inducer, humidifier (both 120V & 24V input) and air cleaner • Includes flash code diagnostics • Twinning
• Fused to protect low voltage system transformers • Adjustable blower relay WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Each
Order #
Mfg. #
OEM Replacement for
L45-392
50T35-743 Goodman: B1809906, B1809908, B1809910, B1809913, B1809913S; UTEC: 1012-933D; Texas Instruments: 41F-5; White-Rodgers: 50T35-730
319.00
358
©2023 Johnstone Supply, LLC
Made with FlippingBook Annual report maker