©Johnstone Supply eCatalog 216

HVAC CONTROLS Time Delays

Delay On Break Timer • One model replaces many in field • Universal voltage anti-short cycle timer • Simple two-wire hookup • Solid state reliability Specifications: • Input: 18 to 240VAC/VDC; output: SPST N.O. 1.5A, 15A in-rush Time Delay Relays • Replacements for Carrier, Day & Night, Bryant, Fraser & Johnson, BorgWarner, Trane, Armstrong, Rheem, Arkla, HeilQuaker, Tappan and Westinghouse gas furnaces • Controls the blower at a predetermined time interval after the heater is energized • Heater is connected to a 24V circuit that is energized remotely by a manual switch, room Order # Mfg. # Time Delay B11-835 ICM203B Adj. 0.03 to 10 Min.

• Time delay: Repeat accuracy ±2% • Range: 0.3 to 10 minutes WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Each

Volts

Switch Action Solid State

18 to 240VAC

41.49

thermostat or some other automatic electric contacting device • Amp rating (between terminals two and four) 13.8A @ 120VAC and 8A @ 240VAC; (between terminals one and four) 5.8A @ 120VAC, 2.9A @ 240VAC WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

Each

Order #

Mfg. #

Time Delay

Switch Action

L36-824 L36-825 L36-826 L36-827 L36-828

S106-1A-45-75C On Time @ 24V 45 Sec. Off Time After 2 Min. On Time 75 Sec. S106-1A-50-40C On Time @ 24V 50 Sec. Off Time After 2 Min. On Time 40 Sec. S106-1A-55-60C On Time @ 24V 55 Sec. Off Time After 2 Min. On Time 60 Sec. S106-1A-40-100C On Time @ 24V 40 Sec. Off Time After 2 Min. On Time 100 Sec. SPST S106-1B-65-45C On Time @ 24V 65 Sec. Off Time After 2 Min. On Time 60 Sec. SPDT SPST SPST SPST

125.00 125.00 125.00 125.00 125.00

1 and 2 Pole Definite Purpose Contactors • Compact design with low VA coil • Sealed housing keeps contaminants out and lowers noise • Includes arc cover

• L36-875 , L36-876 , L36-877 , L36-881 , L36 882 and L36-883 are 1 pole contactors with terminal block to replace 2 pole

Ind. F/L Amps Poles Coil Voltage

Res. Amps

Ind. F/L Amps Poles Coil Voltage

Res. Amps

Each

10 Lot

Each

10 Lot

Order # Mfg. #

Order # Mfg. #

L37-114 L37-115 L36-872 L36-873 L36-874 L36-875 L36-876 L36-877 L37-117 L37-118 L37-119 L36-878 L36-879

L36-883 C25CNB130B 30

C25BNB220T 20 C25BNB220A 20 C25ANB125T 25 C25ANB125A 25 C25ANB125B 25 C25CNB125T 25 C25CNB125A 25 C25CNB125B 25 C25BNB225T 25 C25BNB225A 25 C25BNB225B 25 C25ANB130T 30 C25ANB130A 30

2 24 VAC 30 2 120 VAC 30 1 24 VAC 30 1 120 VAC 30 1 208/240 VAC 30 1+ 24 VAC 30 1+ 120 VAC 30 1+ 208/240 VAC 30 2 24 VAC 30 2 120 VAC 30 2 208/240 VAC 30 1 24 VAC 40 1 120 VAC 40 1 208/240 VAC 40 1+ 24 VAC 40 1+ 120 VAC 40

55.00 49.99 55.00 53.00 55.00 53.00 55.00 47.99 55.00 53.00 55.00 53.00 55.00 53.00 55.00 53.00 55.00 53.00 55.00 53.00 55.00 53.00 55.00 53.00 55.00 53.00 55.00 53.00 42.49 39.99 55.00 53.00

1+ 208/240 VAC 40 2 24 VAC 40 2 120 VAC 40 2 208/240 VAC 40 1 24 VAC 50 1 120 VAC 50 1 208/240 VAC 50 1+ 24 VAC 50 1+ 120 VAC 50 1+ 208/240 VAC 50 2 24 VAC 50 2 120 VAC 50 2 208/240 VAC 50 2 24 VAC 50 2 120 VAC 50 2 208/240 VAC 50

55.00 53.00 45.99 43.49 45.99 43.49 45.99 43.49 95.00 89.00 95.00 89.00 95.00 89.00 85.00 79.00 85.00 79.00 85.00 79.00 65.00 62.00 79.00 75.00 79.00 75.00 85.00 82.00 109.00 105.00 109.00 105.00

L37-120 L37-121 L37-122 L40-335

C25BNB230T 30 C25BNB230A 30 C25BNB230B 30 C25ANF140T 40

L40-333 C25ANF140A 40 L40-334 C25ANF140B 40 L45-982 C25CNB140A 40 L45-983 C25CNB140B 40 L45-981 C25CNB140T 40

L40-771 L40-772 L40-773 L37-843 L37-844 L37-845

C25BNB240T 40 C25BNB240A 40 C25BNB240B 40 C25BNF240T 40 C25BNF240A 40 C25BNF240B 40

L36-880 C25ANB130B 30

L36-881

C25CNB130T 30

L36-882 C25CNB130A 30

Replacement Coils • For use with Eaton 2, 3 and 4 Pole Definite Purpose Contactors

Each

Each

Order # Mfg. #

Coil Voltage Contactor Type

Order # Mfg. #

Coil Voltage Contactor Type

L37-565 L37-566 L40-776 L40-777 L40-778 L40-779

L40-782 L40-785 L40-786 L40-787

9-3125-7 277 VAC 25 to 40A, 2 & 3-Pole (Old Style) 9-3125-3 440 VAC 25 to 40A, 2 & 3-Pole (Old Style)

115.00 115.00 145.00 145.00 145.00 145.00

9-3186-2 208/240 VAC 50A, 2 & 3-Pole

185.00

9-3256-1 104/120 VAC 25 to 40A, 4-Pole & 60 to 75A, 2 & 3-Pole 155.00 9-3256-2 208/240 VAC 25 to 40A, 4-Pole & 60 to 75A, 2 & 3-Pole 155.00 9-3256-7 277 VAC 25 to 40A, 4-Pole & 60 to 75A, 2 & 3-Pole 145.00

9-3185-6 24 VAC 25 to 40A, 2 & 3-Pole 9-3185-1 104/120 VAC 25 to 40A, 2 & 3-Pole 9-3185-2 208/240 VAC 25 to 40A, 2 & 3-Pole 9-3185-7 277 VAC 25 to 40A, 2 & 3-Pole

L40-336 9-3079-2 110/120 VAC 90A, 2 & 3-Pole L40-338 9-2756-1 110/120 VAC 120A, 3-Pole

669.00 505.00

334

©2023 Johnstone Supply, LLC

Made with FlippingBook Annual report maker