©Johnstone Supply eCatalog 216
BELT DRIVE MOTORS 48 Frame Split-Phase
Belt Drive Fan and Blower Motors Split Phase, 48/56 Frame, Open Dripproof Features: • Automatic reset overload protection • 2-1/2" resilient rings • All-angle bearings • 1/2"–5/8" diameter shaft adapter included • Continuous duty, 40°C ambient
• CCW/CW electrically reversible rotation • Fig. A slotted frame, base included: fits 48 and 56 frame mount • Fig. B length adjustable, base not included: 1-1/2" splined hub (OSE) for adjustable mounting
A
B
Each
Fig. Order #
Mfg. #
Diam.
HP
Volts
RPM Speeds F/L Amps Efficiency Shaft Diam.
Shaft Length Rot.
Bearing Type Wt. Lbs.
With Resilient Base A S88-720 4701
5-5/8" 5-5/8" 5-5/8" 5-5/8" 5-5/8" 5-5/8"
1/4 1/3 1/2 1/4 1/3 1/2
115 115 115 115 115 115
1725 1 1725 1 1725 1 1725 1 1725 1 1725 1
5.10 3.70 7.90
— 1/2" 73% 1/2" — 1/2"
1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2"
Rev. Rev. Rev. Rev. Rev. Rev.
Ball Ball Slv Ball Ball Ball
11.6 24.0 19.0 11.7 14.5 17.1
385.00 775.00 615.00 435.00 405.00 545.00
— S82-956
HG700
S82-195
A
D162
With Resilient Rings B S88-723 4730
5.00 — 1/2" 5.80 — 1/2"
S88-724 S88-725
B B
4731 4732
7.90
— 1/2"
Furnace Blower and Fan Duty Motors Split Phase, 48 Frame, Dripproof Features: • Automatic thermal protection • Low starting amps • All-angle sleeve bearing • Resilient mounting furnished • 40°C ambient
• Continuous duty • Reversible rotation • 60 Hz • Class A insulation • Not recommended where automatic reset creates a hazard
Bearing Type
Each
Order # Mfg. # S87-872 D107 S87-876 H167 S87-879 D163
Diam. 5-5/8" 5-5/8" 5-5/8"
HP 1/6 1/3 1/2
Volts 115 230 230
RPM Speeds
F/L Amps Efficiency Shaft Diam. Shaft Length Rot.
Wt. Lbs.
1725 1725 1725
1 1 1
3.60 3.10 3.60
— 1/2" — 1/2" 66% 1/2"
1-1/2" 1-1/2" 1-1/2"
Rev. Rev. Rev.
Slv Ball Slv
12.0 14.0 19.0
395.00 495.00 659.00
Belt Drive Fan Motors Split Phase, 56 Frame, Open Dripproof Applications: • Sleeve bearing motor replacements for furnace blowers, belt driven fans, air coolers and similar applications with moderate torque requirements Features: • Automatic thermal protection
• Continuous duty • All-angle mounting • 40°C rise • Reversible rotation • Complete with resilient base • Not recommended where automatic reset creates a hazard
Shaft Length 1-9/10" 1-9/10"
Bearing Type
Each
Order # Mfg. # S89-656 4114
Diam.
HP 1/2 3/4
Volts
RPM Speeds
F/L Amps Efficiency Shaft Diam.
Rot.
Wt. Lbs.
6-3/10" 6-3/10"
115/230 1725 115/230 1725
1 1
8.00
68% 5/8" 70% 5/8"
Rev. Rev.
SAB 22.0 SAB 24.0
1199.00 1245.00
S88-297
4115
11.20
Furnace Blower and Fan Duty Belt Drive Motor Split-Phase, 56 Frame, Dripproof Features: • Automatic thermal protection • Low starting amps • Resilient mounting furnished • 40°C ambient • Continuous duty • Reversible rotation • High Service Factors • 60 Hz • Class A insulation
• Not recommended where automatic reset creates a hazard
Each
Order # Mfg. # S87-878 D149
Diam.
HP 1/2
Volts
RPM 1725
Speeds
F/L Amps Shaft Diam. Shaft Length Rot.
Bearing Type Wt. Lbs.
6-3/10"
115
1
7.20
5/8"
1-7/8"
Rev.
Ball
20.0
659.00
26
©2023 Johnstone Supply, LLC