©Johnstone Supply eCatalog 216
REFRIGERATION & AIR CONDITIONING Emerson Flow Controls Refrigeration Solenoid Valves
240RA Series Solenoid Valves • Pilot-operated, normally closed diaphragm valves • Complete with manual stem • Especially suited for liquid and suction service • One coil fits all sizes; snap-on coil retainer eases installation and removal • All models listed can be used in hot gas applications
• Maximum fluid temperature: 285°F • Maximum operating pressure differential: 300 PSI • Listed capacity ratings are suggested nominal tonnage • All valves less coil Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Each
Order #
Mfg. #
Port Size
Conn. Size 5/8” ODF 7/8” ODF 5/8” ODF 7/8” ODF 1-1/8” ODF 1-1/8” ODF 1-1/8” ODF 1-3/8” ODF 1-5/8” ODF 7/8” ODF
R12 Capacity
R22 Capacity
R404A Capacity
B12-243 B12-244 B13-821 B12-245 B12-246 B13-817 B12-531 B13-818 B12-532 B13-820
1840052
1/2” 1/2”
10.1 10.1 14.9 19.7 19.7 22.5 22.6 37.3 37.5 58.8
15.6 15.6 23.3 30.5 30.5 34.9 34.9 58.0 58.0 95.4
10.3 10.3 15.1 20.1 20.1 22.7 23.0 37.7 38.3 62.0
265.00 265.00 399.00 399.00 399.00 559.00 559.00 765.00 795.00 1445.00
240RA8T7-M 240RA9T5-M 240RA9T7-M 240RA9T9-M
9/16” 9/16” 9/16”
240RA12T7-M 3/4” 240RA12T9-M 3/4” 250RA16T9MVLC-01 1” 240RA16T11-M 1” 240RA20T13-M 1-1/4”
540RA Solenoid Valves • Two-way, normally open diaphragm valves • For liquid, suction and hot gas service • Can be brazed into line without disassembly • Extended ends for easy installation • Water, shock and vibration protection in coil winding
• Low pressure differential required for full opening • All valves less coil • Capacity ratings listed below are nominal system tonnage Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
Each
Order #
Mfg. #
Port Size
Conn. Size 5/8" ODF 7/8" ODF 7/8" ODF 1-1/8" ODF
R12 Capacity
R22 Capacity
R404A Capacity
B13-830 B13-831 B13-827 B13-828
540RA8T5-T 1/2" 540RA9T7-T 9/16" 540RA12T7 3/4" 540RA16T9-T 1"
10.0 19.6 22.5 37.3
15.6 30.5 34.9 58.0
10.1 19.8 22.7 37.7
425.00 609.00 765.00 1099.00
Constant Pressure Expansion Valves • Maintains minimum evaporator pressure under high load conditions • Controls flood back by controlling overfeeding of the evaporator • Automatically provides motor overload protection during system start-up • For all refrigerants
• Capacity ratings listed below are nominal system tonnage Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov Note: The inlet connection of the B12-512 (Fig. D) is on the bottom of the valve.
A
B
C
D
Each
Fig. Order #
Mfg. #
Inlet Conn. 1/4" SAE 1/4" SAE 3/8" SAE 1/4" SAE 3/8" ODF 3/8" SAE 1/4" ODF 1/4" ODF
Outlet Conn. 1/4" FPT 1/2" SAE 1/2" SAE 1/2" SAE 3/8" ODF 3/8" SAE 3/8" ODF 3/8" ODF
R12/R134a Capacity
R22 Capacity
R502/R404A Capacity
B13-673 B11-658 B13-674 B13-675 B13-676 B13-677 B12-512 B13-672
A B B B C C D D
A-1 A-2 A-3 A-4
1 to 2 1 to 2 1 to 2
1-1/2 to 3 1-1/2 to 3 1-1/2 to 3
1 to 2 1 to 2 1 to 2
305.00 275.00 305.00 295.00 375.00 375.00 295.00 309.00
1/4 to 3/4
1/2 to 1
1/4 to 3/4
A7-A A7-C
1/4 to 1
1/2 to 1-1/2 3-1/2 to 5 1/2 to 1-1/2 1/2 to 1-1/2
1/4 to 1
1-1/2 to 3
1-1/2 to 3
AS
1/4 to 1 1/4 to 1
1/4 to 1 1/4 to 1
ASB20
1259
JohnstoneSupply.com
Made with FlippingBook Annual report maker