©Johnstone Supply eCatalog 216
GENERAL PURPOSE MOTORS 56 Frame C-Face
C-Face Commercial Farm Duty Pump Motors 56C Frame, Totally Enclosed Fan Cooled, Single Phase Applications:
• NEMA service factor • Reversible rotation • No thermal protection • Fig. A: no base • Fig. B: welded base • Capacitor start
• Commercial and industrial pumps, centrifugal and hydraulic pumps, machine tools and other equipment requiring NEMA C-face mounting configurations in dusty or dirty areas Features: • NEMA C-face mounting
A
B
Shaft Length
Bearing Type
Each
Fig. Order # Mfg. #
Diam.
HP Volts
RPM Speeds F/L Amps Efficiency Shaft Diam.
Rot.
Wt. Lbs.
S89-359 S89-357 S89-365 S89-358 S89-362 S89-363
A A B A A B A B
G1511 G1513 C1405 G1515 G1517 C1425
6-3/10" 6-3/10" 6-3/10" 6-3/10" 6-3/10" 6-3/10" 6-3/10" 6-3/10"
1/4 115/230 1/3 115/230 1/3 115/230 1/2 115/230 3/4 115/230 3/4 115/230 1 115/230
1725 1725 1725 1725 1725 1725 1725
1 1 1 1 1 1 1 1
5.40 6.00 6.00 8.60
— 5/8" — 5/8" — 5/8" — 5/8"
2" 2" 2" 2" 2" 2" 2" 2"
Rev. Rev. Rev. Rev. Rev. Rev. Rev. Rev.
Ball Ball Ball Ball Ball Ball Ball Ball
14.0 17.0 17.0 21.0 31.0 31.0 38.0 37.0
739.00 855.00 865.00 985.00 1199.00 1199.00 1299.00 1299.00
11.00 — 5/8" 11.00 — 5/8" 13.20 72% 5/8" 13.20 69% 5/8"
S89-364 G1519
S89-360
C376
1 115/208-230 1725
Quad-Plus™ Capacitor Start C-Face General Purpose Motors 56 Frame, Totally Enclosed Fan Cooled, Single Phase Applications: • Commercial pumps, conveyors, speed reducers and other equipment that mounts directly on NEMA C-face applications Features: • Removable base • Double sealed ball bearing • 1.15 service factor • Class B insulation ( S89-528 has class F insulation) • No overload protection • Reversible rotation • Horizontal, vertical shaft up or shaft down mounting • Standard NEMA C-face shaft: 5/8" x 1.88" with keyway
Shaft Length
Each
Order # Mfg. #
Diam.
HP
Volts
RPM Speeds
F/L Amps Efficiency Shaft Diam.
Rot.
Bearing Type Wt. Lbs.
Capacitor Start S89-529 C823
6-1/2” 6-1/2” 6-1/2”
1/4 1/3 1/3 1/2 3/4
115/208-230 1200 115/208-230 1800 115/208-230 1200 115/208-230 1800 115/208-230 1800 115/208-230 1800
1 1 1 1 1 1
5.00 6.40 6.00 7.20
67% 5/8” 67% 5/8” 67% 5/8” 67% 5/8” 67% 5/8” 67% 5/8”
1-7/8” 1-7/8” 1-7/8” 1-7/8” 1-7/8” 1-7/8”
Rev. Rev. Rev. Rev. Rev. Rev.
Dbl-Sld Ball 26.0 Dbl-Sld Ball 28.8 Dbl-Sld Ball 30.5 Dbl-Sld Ball 19.0 Dbl-Sld Ball 32.0 Dbl-Sld Ball 25.0
1145.00 945.00 1299.00 1145.00 1345.00 1445.00
S89-523
C824
S89-530 C825
S89-524 S89-525 S89-526
C826V1 6-1/2” C828V1 6-1/2” C830V1 6-1/2”
10.40 15.00
1
Capacitor Start, Capacitor Run S89-528 C832 6-1/2” 2
115/208-230 1800
1
17.80
85% 5/8”
1-7/8”
Rev.
Dbl-Sld Ball 32.0
2045.00
C-Face Capacitor Start Motors 56C Frame, Dripproof, Single-Phase Applications: • Commercial and industrial pumps, centrifugal and hydraulic pumps
Features: • NEMA service factor • Reversible rotation Note: Base not included
Shaft Diam.
Shaft Length Rot.
Bearing Type
Each
Order # Mfg. #
Diam.
HP Volts
RPM Speeds F/L Amps
Efficiency
Wt. Lbs.
Replaces
Automatic Thermal Protection S82-950 C356A 6-1/2" 1/3 115/230 S89-295 CG362A 6-3/10" 3/4 115/230
1725 1 1725 1
5.80
87% 5/8" — 5/8"
2" 2"
Rev. Rev.
Ball Ball
19.0 24.0
S89-292
929.00 1399.00
13.20
—
No Thermal Protection S82-547
G234A 6-1/2" 1/2 115/208-230 1800 1
8.60/4.10-4.30
— 5/8"
2"
Rev.
Ball
21.3
—
769.00
121
JohnstoneSupply.com
Made with FlippingBook Annual report maker