©Johnstone Supply eCatalog 216

TECUMSEH PRODUCTS Refrigeration Condensing Units

R134a Condensing Units • All units charged with ester oil and dry nitrogen

• Last letter in mfg. # designates unit features: • A or K: no receiver, with power cord (capillary tube applications) • B: with receiver and power cord • C: with receiver • S: no receiver, with isolation valves

• Pressure control included where listed below • MCA and MFS ratings denote Minimum Circuit Ampacity and Maximum Fuse Size • BtuH capacity ratings below are based on 90°F ambient and listed evaporator temperature

R134a High Temperature Condensing Units Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

BtuH Capacity @ 20°F Evap.

BtuH Capacity @ 25°F Evap.

BtuH Capacity @ 30°F Evap.

BtuH Capacity @ 35°F Evap.

BtuH Capacity @ 40°F Evap.

BtuH Capacity @ 45°F Evap.

Order #

Mfg. #

B/M

Refrigerant HP

Volts

Phase

B73-767 B73-769 B73-771 B73-773 B73-775 B86-167

AE3425Y-AA1ASS 32F560-69S R134a 1/5 AE4430Y-AA1ASC 32F470-59S R134a 1/4 AE4430Y-AA1ASS 32F470-69S R134a 1/4 AE4440Y-AA1ASC 32F360-59S R134a 1/3 AE4440Y-AA1ASS 32F360-69S R134a 1/3 AKA4457YAADC 2G222-59 R134a 1/2

115 115 115 115 115 115

1 1 1 1 1 1

1,460 1,800 1,800 2,360 2,360 3,503

1,640 2,030 2,030 2,610 2,610 3,918

1,840 2,260 2,260 2,860 2,860 4,334

2,040 2,490 2,490 3,110 3,110 4,753

2,250 2,730 2,730 3,370 3,370 5,171

2,800 3,400 3,400 4,350 4,350 5,665

Additional Specifications

Min. Circuit Amps

Max. Fuse Size

Receiver Capacity Lbs. Length

Order #

Mfg. #

Compressor #

Suction Conn. Liquid Conn.

Width 11.5" 11.5" 11.5" 11.5" 11.5"

Height

Wt. Lbs.

B73-767 B73-769 B73-771 B73-773 B73-775 B86-167

AE3425Y-AA1ASS AE3425Y-AA1A 5.0 AE4430Y-AA1ASC AE4430Y-AA1A 6.7 AE4430Y-AA1ASS AE4430Y-AA1A 6.7 AE4440Y-AA1ASC AE4440Y-AA1A 7.9 AE4440Y-AA1ASS AE4440Y-AA1A 7.9 AKA4457YAADC AKA4460YXA 12.3

15 15 15 15 15 20

5/16" ODF 1/4 ODF — 3/8" ODF 1/4 ODF 1.8 5/16" ODF 1/4 ODF — 3/8" ODF 1/4 ODF 1.8 5/16" ODF 1/4 ODF — 1/2" IDS 5/8" IDS 2.5

16" 16" 16" 16" 16" 15"

8.9" 8.9" 8.9" 8.9" 8.9"

42 42 42 42 42 54

14"

11.2"

R134A Medium Temperature Condensing Unit Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

BtuH Capacity @ -10°F Evap.

BtuH Capacity @ 0°F Evap.

BtuH Capacity @ 10°F Evap.

BtuH Capacity @ 20°F Evap.

BtuH Capacity @ 25°F Evap.

BtuH Capacity @ 30°F Evap.

Order #

Mfg. #

B/M

Refrigerant HP

Volts

Phase

B77-895

THB0410YXASC 32G575-59S R134a 1/6

115

1

540

720

950

1,240

1,400

1,560

Additional Specifications

Min. Circuit Amps

Receiver Capacity Lbs. Length

Order #

Mfg. #

Compressor #

Max. Fuse Size Suction Conn. Liquid Conn.

Width 11.5"

Height

Wt. Lbs.

B77-895

THB0410YXASC THA0410YXA 4.2

15

5/16

1/4

1.58

16"

8.9"

38.8

R134A Low Temperature Condensing Units Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

BtuH Capacity @ -40°F Evap.

BtuH Capacity @ -30°F Evap.

BtuH Capacity @ -20°F Evap.

BtuH Capacity @ -10°F Evap.

BtuH Capacity @ -5°F Evap.

BtuH Capacity @ 0°F Evap.

BtuH Capacity @ 10°F Evap.

Order #

Mfg. #

B/M

Refrigerant HP Volts Phase

B76-735 B76-736 B76-739

AE2410YAA1ASC 32F414-59S R134a 1/4 115 1 AE2410YAA1ASS 32F414-69S R134a 1/4 115 1 AE2413YAA1BSC 32F324-59S R134a 1/3 115 1

270 270 470

450 450 700

590 590 980

910 910

1,110 1,110 1,480

1,270 1,270 1,670

1,610 1,610 2,060

1,310

Additional Specifications

Min. Circuit Amps

Receiver Capacity Lbs. Length

Order #

Mfg. #

Compressor #

Max. Fuse Size Suction Conn. Liquid Conn.

Width 11.5" 11.5" 11.5"

Height

Wt. Lbs.

B76-735 B76-736 B76-739

AE2410YAA1ASC AE2410Y-AA1A 4.6 AE2410YAA1ASS AE2410Y-AA1A 4.6 AE2413YAA1BSC AE2413Y-AA1B 5.54

15 15 15

3/8" ODF 1/4" ODF 1.8 3/8" ODF 1/4" ODF 1.8 3/8" ODF 1/4" ODF 1.7

16" 16" 16"

8.9" 8.9" 8.9"

39.5 38.9 39.5

1156

©2023 Johnstone Supply, LLC