©Johnstone Supply eCatalog 216
TECUMSEH PRODUCTS Refrigeration Condensing Units
R12 Condensing Units • Air cooled condensing units • All units charged with dry nitrogen
• A or K: no receiver, with power cord • B: with receiver and power cord • C: with receiver, power cord, and service valves • S: no receiver, with service valves and power cord
• Pressure control included where listed below • MCA and MFS ratings below denote Minimum Circuit Ampacity and Maximum Fuse Size • Last letter in mfg. # designates unit features:
R12 High Temperature Condensing Units Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
BtuH Capacity @ 10°F Evap.
BtuH Capacity @ 20°F Evap.
BtuH Capacity @ 25°F Evap.
BtuH Capacity @ 30°F Evap.
BtuH Capacity @ 35°F Evap.
BtuH Capacity @ 40°F Evap.
BtuH Capacity @ 45°F Evap.
Order #
Mfg. #
B/M
Refrigerant HP Volts Phase
B76-722 B76-724 B76-725
AE4430AAA1ASC 32F472-59S R12 AE4440AAA1ASC 32F362-59S R12 AE4440AAA1ASS 32F362-69S R12
1/4 115 1 1/3 115 1 1/3 115 1
1,620 2,120 2,120
2,070 2,640 2,640
2,320 2,920 2,920
2,590 3,200 3,200
2,870 3,500 3,500
3,160 3,810 3,810
3,480 4,120 4,120
Additional Specifications
Max. Fuse Size
Receiver Capacity Lbs. Length
Order #
Mfg. #
Compressor #
Min. Circuit Amps
Suction Conn. Liquid Conn.
Width 11.5" 11.5" 11.5"
Height
Wt. Lbs.
B76-722 B76-724 B76-725
AE4430AAA1ASC AE4430A-AA1A 6.72 AE4440AAA1ASC AE4440A-AA1A 7.86 AE4440AAA1ASS AE4440A-AA1A 7.86
15 15 15
3/8" ODF 1/4" ODF 2.6 3/8" ODF 1/4" ODF 2.6 3/8" ODF 1/4" ODF 2.6
16" 16" 16"
8.9" 8.9" 8.9"
39.5 39.5 39.5
R12 Low Temperature Condensing Unit Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
BtuH Capacity @ -40°F Evap.
BtuH Capacity @ -30°F Evap.
BtuH Capacity @ -20°F Evap.
BtuH Capacity @ -10°F Evap.
BtuH Capacity @ -5°F Evap.
BtuH Capacity @ 0°F Evap.
BtuH Capacity @ 10°F Evap.
Order #
Mfg. #
B/M
Refrigerant HP Volts Phase
B76-742
AE2413AAA1BSC 32F326-59S R12
1/3 115 1
740
790
1,330
1,760
1,930
2,090
2,280
Additional Specifications
Min. Circuit Amps
Max. Fuse Size
Receiver Capacity Lbs. Length
Order #
Mfg. #
Compressor #
Suction Conn. Liquid Conn.
Width 11.5"
Height
Wt. Lbs.
B76-742
AE2413AAA1BSC AE2413A-AA1B 5.79
15
3/8" ODF 1/4" ODF 2.6
16"
8.9"
39.5
R22 Condensing Units • Pressure control included, where listed • MCA and MFS ratings denote Minimum Circuit Ampacity and Maximum Fuse Size • Units 2 HP and larger have dual fan cycle controls • BtuH capacity ratings below are based on 90°F ambient and listed evaporator temperature
• Last letter in mfg. # designates unit features: • A or K: no receiver, with power cord (capillary tube applications) • B: with receiver and power cord • C: with receiver • M: with suction accumulator • S: no receiver, with isolation valves
w
R22 Commercial Temperature Condensing Unit Warning: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
BtuH Capacity @ 40°F Evap.
BtuH Capacity @ 30°F Evap.
BtuH Capacity @ 25°F Evap.
BtuH Capacity @ 20°F Evap.
BtuH Capacity @ 10°F Evap.
BtuH Capacity @ 0°F Evap.
BtuH Capacity @ -10°F Evap.
Order #
Mfg. #
B/M
Refrigerant HP
Volts
Phase
B86-176
AKA9435EAADC 2G303-59 R22
1/2
115
1
1,600
2,124
2,760
3,510
3,928
4,373
5,349
Additional Specifications
Min. Circuit Amps
Receiver Capacity Lbs. Length
Order #
Mfg. #
Compressor #
Max. Fuse Size Suction Conn. Liquid Conn.
Width
Height 11.5"
Wt. Lbs.
B86-176
AKA9435EAADC AKA9428EXA 9.5
15
1/2" ODF 3/8" ODF 2.5
15"
14"
54
1154
©2023 Johnstone Supply, LLC